This section explains what you need to do when you change the module configuration (by installing or removing modules).

Reconfiguring the GX/GP (Module identification)

Reconfiguring the GX/GP

When you reconfigure the GX/GP and the GX60, the
installed I/O modules are detected, and the settings are
changed accordingly.
Reconfiguration is necessary in the following situations.
• If you specify modules separately
• If you change the modules (change to different modules)
• If you add or remove modules
• If you connect the GX60
• When the measurement mode is changed
• When the advanced security function on/off state is
changed
If you purchased a model with preinstalled modules (/U[]
[]0 or /CR[][] option), you can start using the GX/GP right
away without any reconfiguration. However, if you connect
the GX60, change modules, add modules, or delete
modules, you will need to reconfigure.
Note
You cannot reconfigure GX/GP while recording start
,math start, controled.
1
Press MENU.
2
Tap the Browse tab.
3
Tap Initialize Calibration.
4
Tap Reconfiguration.
5
Tap Execute.
The system information appears.
XX - X X - XX - X X -X X - X X
RX . XX . X X
6
Tap Reconfigure.
7
Tap OK.
Note
Do not carry out the following operations while the GX/
GP is reconfiguring.
Turn the power off and on
Insert or remove modules
This procedure is not necessary if you purchased an I/O
module preinstalled model and do not need to change the
configuration.
46
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550
X XX XX XX XX
RX . X X. X X
6
Operation complete
Initializing the GX/GP
(Initializing all settings)
Initialize the GX/GP after reconfiguring the GX/GP when
channels are not assigned to display groups. Channels
are automatically assigned during initialization.
For details, see the User's Manual (IM 04L51B01-01EN).
Note
This procedure is not necessary if you purchased an
I/O module preinstalled model and do not need to
change the configuration.
If you initialize, setting parameters are reset to their
factory defaults. We recommend that you back up
setting parameters before initialization.
1
Press MENU.
2
Tap the Browse tab.
3
Tap Initialize Calibration > Initialize > Settings/
Inter data.
4
Tap Initialize all > On.
5
Tap Execute.
A confirmation screen is displayed.
6
Tap OK.
The settings are initialized.