Appendix A: Using the LCD Console
To configure the RaQ 4 for the UPS, first connect the UPS unit and the RaQ 4,
and then configure the RaQ 4 through the LCD panel. (Refer to the UPS manual
for more information on connecting the devices.)
1.
Plug the UPS into the wall socket.
2.
Turn on the UPS.
3.
Plug the RaQ 4 servers into the UPS power sockets.
4.
Connect the UPS serial cable to the UPS unit and the serial port on the
RaQ 4 that will serve as the master. See Figure 58.
Important: You must use the serial cable shipped with the UPS
unit.
5.
On the LCD console, hold down the
2 seconds.
The LCD screen displays:
SELECT:
SETUP NETWORK
6. Press the
S
SELECT:
CONFIGURE UPS
7.
Press the
E
8. Use the arrow buttons to toggle the cursor between [ ] On and [ ] Off.
Select [ ] On.
9.
Press the
E
10. Use the arrow buttons to toggle the cursor between [M]aster and [S]lave.
11. Press the
E
automatically for the UPS.
152
button until Configure UPS appears in the LCD screen:
button.
button.
button. If you choose [M]aster, the RaQ 4 configures itself
Cobalt RaQ 4 User Manual
button for approximately
S