Download Print this page
Paradox REM3 Instructions

Paradox REM3 Instructions

Hand-held 2-way remote keypad

Advertisement

Quick Links

REM3-EI07
REM3
Hand-Held 2-Way Remote Keypad
Printed in Canada 01/2012
Introduction
The REM3 combines the flexibility of a keypad with the convenience
and mobility of a remote control. Its 15 buttons allow for a greater level
of interaction with the system than regular remote controls, and the two-
way transceiver allows for accurate feedback for up to 2 partitions.

Technical Specifications

RF frequency
433MHz or 868MHz
Battery type
One 3V lithium battery (2032)
Battery life
Battery life expectancy is a minimum of 1 year.
"Low Battery Signal" is sent to the control panel when
battery is below 2.2Vdc. Upon power-up, a "Low
Battery Restore Signal" is sent to the control panel
when the battery voltage level has reached 2.7Vdc or
higher.
Range (typical in a
45m (150ft)
residential environment)
Compatibility
MG5000 / MG5050 V3.0 and higher /
Spectra SP Series V3.0 and higher in conjunction
with a RTX3 V1.31 and higher.
IMPORTANT: The REM3 is not compatible with the
RPT1 and will not benefit from the additional range.
Dimensions
8cm x 3.4cm x 1.5cm (3.1in x 1.3in x 0.6in)
Standards
EN 50131-3 Grade 2 Class II
Assigning the REM3 to the Panel
Step Action on Keypad
1
[
] + [
]
MASTER CODE
2
[
]
USER NUMBER
3
[
]
CODE
4
[
]
CONFIRM CODE
5
[
]
LEARN REMOTE
6
[1] and/or [2] + [
]
ENTER
One-touch Arm Keys
The REM3 offers the use of one-touch arm keys. The use of one-touch
arm keys must be enabled in section [703], options [1] to [3] in the
panel.
[703]
Arming/Disarming Options 1
Option
[1]
One-touch regular arming
[2]
One-touch stay arming
[3]
One-touch sleep arming
V1.0
Instructions
Details
The [
] key will flash.
LED/key on = programmed user.
[
] may also be used.
PARTITION MASTER CODE
2 digits: 01 to 32
Enter 4- or 6-digit code
Re-enter 4- or 6-digit code
Press and hold the Information key ([i]) on
the designated remote. Important: For parti-
tioned systems, go to step 6. For non-parti-
tioned systems, go to step 2 to add another
remote or press [
] to exit.
CLEAR
Assign the user to one or both partitions, then
press [
].
ENTER
Go to step 2 or press [
] to exit.
CLEAR
OFF
ON
 Disabled
 Enabled
 Disabled
 Enabled
 Disabled
 Enabled
See reverse for REM3 Diagnostic Mode instructions.
PGM Key Assignment
The REM3 provides six PGM keys. See sections [610] to [642] in the panel to
define the six PGM keys and two combo keys:
PGM1
PGM2
[9]
[0]
[B]
[C]
Default:
___
___
[610]
ALL RC
S
IMPORTANT: When section [610] is accessed, the panel will copy the saved value of that
section to all remotes.
___
___
[611]
RC#1
___
___
___
___
[642]
RC#32
PGM Key Definitions Table
[
] - Empty / Button disabled
SLEEP
[1] - Regular / Regular Force arming
[2] - Stay / Stay Force arming
[3] - N/A
[4] - Sleep / Sleep Force arming
[5] - PGM Activation (Event Group #22)
[6] - PGM Activation (Event Group #23)
[7] - N/A
One-Touch Programming
Program the REM3 to enable one-touch mode to disarm your system and/or
trigger PGMs. By default, the REM3 is set to require code entry. Section [360]
is used to configure all odd and even-numbered REM3s, while sections [361]
to [376] are used to configure REM3s by pairs.
[360] Odd-Numbered REM3s
[1] PGM activate/deactivate
[2] Disarm
[3] & [4]
Even-Numbered REM3s
[5] PGM activate/deactivate
[6] Disarm
[361] REM3 #1
[1] PGM activate/deactivate
[2] Disarm
[3] & [4]
REM3 #2
[5] PGM activate/deactivate
[6] Disarm
[376] REM3 #31
[1] PGM activate/deactivate
[2] Disarm
[3] & [4]
REM3 #32
[5] PGM activate/deactivate
[6] Disarm
PGM3
PGM4
PGM5
PGM6
[x]
[]
[ ]
[ ]
[D]
[E]
[5]
[6]
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
[8] - Panic 1
[9] - Panic 2
[A] - Panic 3
[B] - PGM Activation (Event Group #8)
[C] - PGM Activation (Event Group #9)
[D] - PGM Activation (Event Group #10)
[E] - PGM Activation (Event Group #11)
[F] - Paramedic alarm
OFF = Code entry
ON = One-touch
OFF = Code entry
ON = One-touch
N/A
N/A
OFF = Code entry
ON = One-touch
OFF = Code entry
ON = One-touch
OFF = Code entry
ON = One-touch
OFF = Code entry
ON = One-touch
N/A
N/A
OFF = Code entry
ON = One-touch
OFF = Code entry
ON = One-touch
OFF = Code entry
ON = One-touch
OFF = Code entry
ON = One-touch
N/A
N/A
OFF = Code entry
ON = One-touch
OFF = Code entry
ON = One-touch
PGM
PGM
[x] + []
[ ] + [ ]
[
]
[
]
SLEEP
SLEEP
___
___
___
___
___
___
___
___

Advertisement

loading

Summary of Contents for Paradox REM3

  • Page 1: Technical Specifications

    REM3-EI07 REM3 PGM Key Assignment The REM3 provides six PGM keys. See sections [610] to [642] in the panel to define the six PGM keys and two combo keys: Hand-Held 2-Way Remote Keypad PGM1 PGM2 PGM3 PGM4 PGM5 PGM6 V1.0 []...
  • Page 2 6104319, 5920259, 5886632, 5721542, 5287111, and RE39406 and other pending patents may apply. Canadian and international patents may also apply. REM3 is a trademark or registered trademark of Paradox Ltd. or its affiliates in Canada, the United States and/or other countries. For the latest information on products...