Enable/Disable The Auto-Track; Enable/Disable The Displacement Detection; Enable/Disable The Reed Switch - Bosch SEC-3402-304 Installation Manual

Sec-3402 series. security escort point tracking transmitter
Table of Contents

Advertisement

Security Escort Point Tracking Transmitter
Radio Frequency
304 MHz (default setting)
303.825 MHz
Tab. 4.1: Radio frequency (RF) settings on dip switch
4.3

Enable/disable the auto-track

Enable or disable the auto-track feature by setting switch number 2 on the dip switch. Set
switch number 2 to the OFF position to disable the auto-track feature. Set switch number 2 to
the ON position to enable the auto-track feature. Once enabled, an alarm will trigger the
transmitter to send a signal back to the Central Console every 7 seconds for a period of 15
minutes.
Auto-track Feature (7 seconds)
Disable (default setting)
Enable
Tab. 4.2: Auto-track setting on dip switch
4.4

Enable/disable the displacement detection

Enable or disable the displacement detection feature by setting switch number 3 on the dip
switch. Set switch number 3 to the OFF position to disable the displacement detection
feature. Set switch number 3 on the dip switch to the ON position to enable the displacement
detection feature. Once enabled, any movements of the transmitter will send a signal back to
the Central Console.
Displacement Detection Feature
Disable (default setting)
Enable
Tab. 4.3: Displacement detection setting on dip switch
4.5

Enable/disable the reed switch

Enable or disable the reed switch feature by setting switch number 4 on the dip switch. Set
switch number 4 to the OFF position to disable the reed switch feature. Set switch number 4
to the ON position to enable the reed switch feature. Once enabled, the transmitter would be
able to detect the state of the attached electromagnetic circuitry.
Reed Switch Feature
Disable (default setting)
Enable
Tab. 4.4: Reed switch setting on dip switch
Robert Bosch (SEA) Pte Ltd
Installation Manual
Enabling and Disabling Features | en
Switch Number on Dip Switch
1
OFF
ON
Switch Number on Dip Switch
2
OFF
ON
Switch Number on Dip Switch
3
OFF
ON
Switch Number on Dip Switch
4
OFF
ON
2018.01 | SE3v1.0 | DL
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sec-3402-433Security escort sec 3402 seriesSecurity escort sec-3402-304Security escort sec-3402-433

Table of Contents