Enabling and Disabling Features
The features of SEC-3402 series can be set, enabled or disabled accordingly using its dip
switch. There are 6 switches on the dip switch. Usage of the dip switch is explained as of
below:
Switch Number
Notice!
Remove the battery before setting the dip switches. Changes to the dip switches should be
performed by administrators only.
4.1
Default dip switch setting
The default setting of the SEC-3402 series dip switch is as follows:
Default Setting
Switch
Position
4.2
Setting the radio frequency (RF)
Set switch number 1 on the dip switch to configure the RF of the device. This setting is not
applicable for the SEC-3402-433 model as its RF is fixed as 433 MHz. The following settings
are configurable for the SEC-3402-304 model.
2018.01 | SE3v1.0 | DL
Usage
1
Frequency Selection:
OFF - 304 MHz (default setting)
ON - 303.825 MHz
(Not applicable to SEC-3402-433)
2
Auto-track (every 7 seconds)
3
Displacement Detection
4
Reed Switch
5
Buzzer
6
Not Used
1
OFF
Installation Manual
Switch Number on Dip Switch
2
3
OFF
OFF
Security Escort Point Tracking Transmitter
4
5
OFF
OFF
Robert Bosch (SEA) Pte Ltd
6
(not used)
OFF