11 Lift the test weights off the platform floor using a
suitable lifting device.
Result: The platform overload indicator light and
alarm should turn off at both the ground and
platform controls.
There may be an approximate 2
second delay before the overload
indicator light and alarm turn off.
12 Test all machine functions from the ground
controls.
Result: All ground control functions should
operate normally.
13 Turn the key switch to platform control.
14 Test all machine functions from the platform
controls.
Result: All platform control functions should
operate.
If the platform overload system is
not operating properly, see D-6,
Calibrate the Platform Overload
System.
Part No. 106373
Section 3 • Scheduled Maintenance Procedures
Genie Z-30/20N
CHECKLIST C PROCEDURES