SC-F2100 Series
User's Guide
If you have worked up to step 6 and then return to
step 1 to re-adjust the platen gap, move the platen
gap adjustment lever by one scale to the smaller
values.
Note:
If you remove both spacers, you cannot check the
scale. In this situation, the position you move the
platen gap adjustment lever to at the far right is
position 8.
When re-adjusting, adjust the platen gap
adjustment lever by one scale at a time making sure
you can feel it click.
D
Tighten the fixing lever, and then secure the
platen gap adjustment lever.
Note:
❏ Print quality may decline if you do not tighten
the fixing lever.
❏ You can adjust the fixing lever to any angle.
Adjust the angle of the lever if it is difficult to
see the scale, or if it is difficult to pass the fabric
of the T-shirt underneath. When adjusting,
change the position while pulling the lever
toward you.
E
Press the } button to move the platen into the
printer.
Basic Printing
F
Check if Platen Height Error is displayed on the
control panel.
When the error is displayed
Go to step 7.
When the error is not displayed
Repeat the following steps until the error is
displayed.
Return to step 1 and when you reach step 3, move
the platen gap adjustment lever by one scale to
the smaller values. The platen rises reducing the
gap. Continue to step 6, and check if an error is
displayed.
G
Set the platen gap to a suitable value
Return to step 1 and when you reach step 3, move
the platen gap adjustment lever by two scales to
the smaller values.
Continue to step 6, and if the error is not
displayed, adjustment is complete.