Watch-Dog Timer - IBM NuPRO-630 Manual

Pentium-ii bus-100mhz vga, full size all-in-one pc/104 vga crt interface, supports dma33 wdt doc usb irda, picmg bus industrial single board computer
Table of Contents

Advertisement

2.12 Watch-Dog Timer

There are three access cycles of Watch -Dog Timer as Enable, Refresh and Disable.
The Enable cycle should proceed by READ PORT 443H. The Disable cycle
should proceed by READ PORT 043H. A continue Enable cycle after a first
Enable cycle means Refresh.
Once if the Enable cycle activity, a Refresh cycle is request before the time-out
period for restart counting the WDT Timer's period. Otherwise, it will assume
that the program operation is abnormal when the time counting over the period
preset of WDT Timer. A System Reset signal to start again or a NMI cycle to the
CPU comes if over.
The JP5 is using for select the active function of watch -dog timer in disable the
watch -dog timer, or presetting the watch -dog timer activity at the reset trigger, or
presetting the watch -dog timer activity at the NMI trigger.
JP5 : Watch-Dog Active Type Setting
l
JP5
*1-2
2-3
OFF
JP6 : WDT Time - Out Period
l
PERIOD
*1 sec
2 sec
10 sec
20 sec
110 sec
220 sec
The Watch -dog timer is disabled after the system Power-On. The watch -dog
timer can be enabled by a Enable cycle with reading the control port (443H), a
Refresh cycle with reading the control port (443H) and a Disable cycle by reading
the Watch -dog timer disable control port (043H). After a Enable cycle of WDT,
user must constantly proceed a Refresh cycle to WDT before its period setting
comes ending of every 1, 2, 10, 20, 110 or 120 seconds which pre-setting by JP6.
2-8 Hardware Installation
DESCRIPTION
System Reset
Active NMI
disable Watch -dog timer
1-2
3-4
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
5-6
7-8
ON
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON

Advertisement