Page 3
General index. 5.2.3. output terminals (only in SPS AdvAnCe T 3 kvA models). 1. INTRODUCTION. 5.2.4. Connection to the optional battery module (backup 1.1. ThAnk yoU LeTTeR. extension). 2. SAfETY INfORMATION. 5.2.5. Terminals for ePo (emergency power off). 2.1. USIng ThIS mAnUAL. 5.2.6.
Page 4
SALICRU is capable of causing The equipment described herein •...
1.1.1 of document ek266*08 The documentation of any standard equipment is available to the "Safety instructions". customer on our website for download (www.salicru.com). for devices “powered by socket”, this is the website for • “Safety Instructions”...
It is also not recommended in medical applications, commercial transport, nuclear installations, or other applications or loads, where a failure of the product can lead to per- sonal or material damages. SALICRU...
Page 7
4. PRESENTATION. 4.1. views. 4.1.1. views of the device. fig. 1 and fig. 2 correspond to SPS AdvAnCe R devices and fig. 3 and fig. 4 to SPS AdvAnCe T devices. however, because the product is constantly evolving, discrepancies or slight contra- dictions may arise.
Page 8
3000 vA model. Control panel with LCd display Plastic front Plastic front trim trim front view of the device. front view of the battery module. Fig. 3. Front view of SPS ADVANCE T devices according to power and battery modules. SALICRU...
Page 9
850 to 2000 vA models. 1000 to 2000 vA b1 models. RS232 Com USb Com RS232 Com USb Com port port port port for connection to for connection to external ePo external ePo Smart slot protective cover IeC AC output sockets IeC AC output AC power...
Page 10
Initials of the battery family. number of batteries in one branch. number of branches in parallel. omit for one. battery module without them, but with the necessary acces- sories to install them. Adv T battery module series. mod bAT battery module. SALICRU...
Model Type Input/output type Integration into computer networks using an SnmP SPS 750 ADV R adapter. SPS 1000 ADV R Single-phase / Single-phase. SPS 1500 ADV R Tab. 1. SPS ADVANCE R standardised models. USER MANUAL...
4.4.3. extendable guide kits for mounting in a rack cabinet (only in sps advanCe r models). An extendable and unique guide kit is available for all SPS AdvAnCe R device models, valid for any kind of rack-type cabinet. SALICRU...
5. INSTALLATION. 2 metal pieces for use as handles and screws for – installing the unit in a rack cabinet (only in SPS Read and respect the Safety Information, described AdvAnCe R models). • in chapter 2 of this document. failure to obey some optional battery module (only in AdvAnCe T models): ...
Page 14
Fig. 7. SPS ADVANCE R mounting in a 19” cabinet. If the isolated output neutral is required, this bridge must be removed, taking the precautions indicated in the respec- tive local and/or national low voltage regulations. SALICRU...
Page 15
This device is suitable for installation in networks 5.2.1. Connection of the input. • with TT, Tn-S, Tn-C or IT power distribution sys- tems, taking into account at the time of installation the As the device has Class I protection against electric •...
Page 16
where it is inserted. This connector has a cable con- nected as a jumper that closes the circuit (see fig. 9A). SALICRU...
Page 17
streamlines warranty procedures in the event of inci- dents: enter the following in the browser's address bar: – https://support.salicru.com. Click the ‘enter’ key. The website’s on-Line Support – page will be displayed on the screen. Register as a user.
“normal mode” without interrupting the power supply at the output. In the AdvAnCe T, the fan or fans, according to the model, • will be put into operation depending on the % of load con- nected to the output. SALICRU...
7. CONTROL PANEL WITh LCD DISPLAY. Button Description - Starting up the UPS. with the UPS off, press the button for at least 2 s ON/Off - Shutting down the UPS. 7.1. ComposiTion of The ConTrol panel wiTh lCd with the UPS on, press the button for at least 2 s display.
Page 20
Select SW button Input backup battery output Charge voltage time level voltage level Start Press > 3 sec (disable audible warning) Repeat press > 3 sec (enable audible warning) v+error other alarms and faults code Tab. 8. Standby operating mode. SALICRU...
Information represented in battery mode. • State of the UPS Level Value Select SW button Input backup battery output Charge voltage time level voltage level Start 1st click 2nd click 3rd click (return to Start) Press > 3 sec (disable audible warning) Repeat press >...
Symptom Possible cause Solution ePo activated: Connect ePo terminals open ePo terminals disconnect non-essential loads from device. overtemperature: Check that fan is working correctly and that UPS’s air inlets and outlets have not been Ambient temperature too high. blocked. Low inverter output voltage: Check AC input connection.
2,400 masl (power degradation up to 5,000 m) Relative humidity. 0..90 % non-condensing. Protection rating. IP20 dimensions (mm) depth x width x height. 216x433x44 (1 U) 485x433x44 (1 U) weight (kg). 14.2 16.2 en IeC 60950-1 Safety. en IeC 60240-1 electromagnetic compatibility (emC). en IeC 60240-2 SALICRU...
Page 25
Models. ADVANCE R Available power ratings (VA / W). 750VA / 450W 1000VA / 600W 1500VA / 900W marking. Quality and environmental management. ISo 9001 and ISo 140001 (certified by SgS) Tab. 14. ADVANCE R general technical specifications. Models. ADVANCE T Available power ratings (VA / W).
Page 26
An insulated gate bipolar transistor is a semicon- Rectifier.- In electronics, a rectifier is the element or cir- • • ductor device that is generally used as a controlled switch cuit that converts AC into dC. This is done by using rectifier SALICRU...
Page 27
diodes, whether solid state semiconductors, vacuum valves or gaseous valves, such as those containing mercury va- pour. depending on the characteristics of the AC power that they use, they are classified as single-phase when they are powered by a mains phase or three-phase when they are powered by three phases.
Page 28
100 08460 palautordera BARCELONA Tel. +34 93 848 24 00 fax +34 93 848 22 05 services@salicru.com SALICRU.COM The Technical service and support (T.s.s.) network, Commercial network and warranty information are available in website: www.salicru.com Product Range...