UNINTERRUPTIBLE POWER SUPPLY (UPS) + LIGHTING FLOW DIMMER STABILIZERS (ILUEST) + SWITCH MODE POWER SUPPLY + STATIC INVERTERS + PHOTOVOLTAIC INVERTERS + VOLTAGE STABILIZERS AND POWER LINE CONDITIONERS
UNINTERRUPTIBLE POWER SUPPLY
SPS SOHO+ series
USER'S MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPS SOHO+ series and is the answer not in the manual?

Questions and answers

Summary of Contents for Salicru SPS SOHO+ series

  • Page 1 UNINTERRUPTIBLE POWER SUPPLY (UPS) + LIGHTING FLOW DIMMER STABILIZERS (ILUEST) + SWITCH MODE POWER SUPPLY + STATIC INVERTERS + PHOTOVOLTAIC INVERTERS + VOLTAGE STABILIZERS AND POWER LINE CONDITIONERS UNINTERRUPTIBLE POWER SUPPLY SPS SOHO+ series USER’S MANUAL...
  • Page 3: Table Of Contents

    Battery maintenance. 6.2.1. Notes for installing and replacing the batteries. 6.3. SPS troubleshooting guide. 6.4. Warranty conditions. 6.4.1. Covered product. 6.4.2. Warranty terms. 6.4.3. Out of scope of supply. 6.5. Technical service network. Annexes. 7.1. General technical specifications. 7.2. Glossary. SALICRU...
  • Page 4: Introduction

    Yours sincerely. • «Earth bonding terminal». Connect the earth cable coming from the load and the external battery cabinet to SALICRU this terminal. • Preservation of the environment: The presence of ˆ The equipment here described can cause important this symbol in the product or in their associated docu- physical damages due to wrong handling.
  • Page 5: General Safety Warnings

    Check the quality and availability of the earth, it has to be between the defined parameters by the local or national regulations. • For the smallest devices (the ones connected with the fore- seen power cord with plug), the user has to check the wall SALICRU...
  • Page 6: To Keep In Mind

    • When it is needed to remove the protection cover to access 1.2.3.2. To keep in mind. to the terminals, they will have to be put back before starting • Do not try to dismantle or change any part of the up the equipment.
  • Page 7 • In case of contact of the acid with parts of the body, wash immediately with plenty water and call urgently the nearest medical service. • Batteries involve a serious risk for the health and for the en- vironment. Their disposal should be done according to the existing laws. SALICRU...
  • Page 8: Quality And Standard Guarantee

    Quality and standard 2.3. Environment. guarantee. This product has been designed to respect the environment and has been manufactured in accordance with the standard ISO 14001. 2.1. Declaration of the management. Equipment recycling at the end of its useful life: Our company commits to use the services of authorised socie- Our target is the client’s satisfaction, therefore this Management ties and according to the regulations, in order to treat the recov-...
  • Page 9: Views Of The Equipment

    2. Cooling Fan. 3. AC Output. 3. AC Output. 4. AC Input. 4. Modem/Phone Line Surge Protection. 5. Circuit breaker. 5. AC Input. 6. Breaker. Fig. 2. Rear view from SOHO+ 400/600/800 VA. Fig. 4. Rear view from SOHO+ 1000/1400/2000 VA. SALICRU...
  • Page 10: Structural Diagram

    (Boost-up / Back down) Bypass Charger Batteries Inverter Fig. 6. SPS SOHO+ series block diagram. 3.5. Operating principle. The SPS is an off-line, interactive Uninterrupted Power Supply System (electronic Boost-up / Back-down stabiliser),controlled by microprocessor. With the unit running, it works as follows: • With the mains present at between 75 % and 125 % the...
  • Page 11: Equipment Reception

    EN-IEC 62040-1. To calculate the input current, the power factor and the efficiency of the equipment have been considered. Overload conditions are considered as nonpermanent and exceptional operating mode. SALICRU...
  • Page 12: Communication Ports

    Fig. 8. Power supply connection. • Installation procedure: ˆ Go to website: http://support.salicru.com 4.4.2. Output connection. ˆ Choose the operating platform that you need and follow the instructions described in the web site to download the Connect one computer-related device into each of the power re- software.
  • Page 13: Lcd Display

    LINE MODE (AVR) Load level Battery bar indication OUTPUT (Unit: V AC) 0.. 25 % FAULT BACKUP MODE 25.. 50 % BATTERY CAPACITY 50.. 75 % LOAD LEVEL 75.. 100 % Fig. 12. LCD display. Table 1. Load level. SALICRU...
  • Page 14 • Battery capacity definition: Battery level Battery bar indication Battery voltage ≤ 11 V 11 V ≤ Battery voltage ≤ 11,5 V 11,5 V ≤ Battery voltage ≤ 12,5 V Battery voltagea ≥ 12,5 V Table 2. Battery level. • When over load, the mark will flicker every 1 second.
  • Page 15: Basic Maintenance Guide

    Therefore, before doing any reparation or maintenance task, the internal battery fuses have to be removed and/or the in- of your business. terlink connections between them and the SPS. SALICRU...
  • Page 16: Covered Product

    6.4.1. Covered product. SPS SOHO+ series. 6.4.2. Warranty terms. See product conditions as in Website. 6.4.3. Out of scope of supply. Our company is not forced by the warranty if it appreciates that the defect in the product doesn’t exist or it was caused by...
  • Page 17: General Technical Specifications

    Comission 61000-1-1) as «the capacity of any de- vice, equipment or system to operate in suitable way in its electromagnetic environment without making electromag- netic perturbations over anything in that environment». • VA.- Voltampere is the unit of the apparent power in alter- SALICRU...
  • Page 18 nating current. In the direct current is almost equal to the real power but in the alternating current it can be different de- pending on the power factor. The voltamperes are arithmetic product of the multiplication between the voltage and current. • LCD.- LCD are the English acronyms of Liquid Crystal Dis- play.
  • Page 19  : ............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................ SALICRU...
  • Page 20 BARCELONA Tel. +34 93 848 24 00 902 48 24 00 (Only Spain) Fax. +34 94 848 11 51 salicru@salicru.com Tel. (S.T.S.) +34 93 848 24 00 902 48 24 01 (Only Spain) Fax. (S.T.S.) +34 93 848 22 05 sst@salicru.com...

Table of Contents