Free standing

The dryer stands on the floor and can easily be moved
into position.
1. Move the dryer into the desired position. Do not lift
the dryer by the top panel.
2. Have a minimum clearance on all sides of at least
20 mm.
3. Have a minimum clearance at the rear of 75 mm.
The spacers from the accessory wall mounting kit
can be used to set this distance.
4. Install the dryer on a stable and level floor.
Free standing venting options
The vent system should be
a maximum of 2 metres
with no more than three 90°
bends.

Through-wall venting

The dryer is vented directly through the wall using Kit
part number PD-SVHCW4, in combination with the duct
adaptor supplied with the dryer. The dryer is vented with
a kit that can be positioned to remove the air to the side.
Kit part number PD-DK4W.
Movable venting
The dryer is vented through a window using Kit part
number PD-F0408, in combination with the duct adaptor
supplied with the dryer. This requires the dryer to be a
minimum distance of 140 mm from the wall to ensure the
ducting is not restricted with tight bends or can be
crushed.
Before a rear venting option is installed the dryer must
be changed from the front venting factory setup.
Remove the outlet grille from the front left-hand side and
https://producthelp.fisherpaykel.com/au/Dry/Dryers/Vented/DE6060P1/User_Guide_DE6060P1/03_Installation_instructions
Through-wall venting with kit
Through-wall venting