Clean And Filter; Oqs - Frymaster FilterQuick Version 2 Operation Manual

Table of Contents

Advertisement

Left Display
Right Display
CLEAN
AND
FILTER
01:00
DELAY
timeR
CLEAN
AND
(300F)
FILTER
(149°C)
start
TEMPR
CHANGE
FILTER
PAD
25
INTERVAL
H

OQS

DISABLED
Exit
Exit
E-LOG
OFF
OFF
PRODUCT
SETUP
Enter
VAT SETUP
code
SYSTEM
E-LOG
NOW
Time/date
A thru j
Time/date
Exit
Exit
CHANGE
PASSWORD
OFF
OFF
PRODUCT
SETUP
Enter
VAT SETUP
code
SYSTEM
CHANGE
PASSWORD
Product
1650
setup
Vat setup
1656
Exit
Exit
Use numbered keys to change time (use 10 for 0). (This is the amount of time which an
operator can delay the start of a clean and filter delay timer.) If the delay time = 0, no
delay is allowed. Press . After the delay the operator must perform a clean and filter.
Use numbered buttons to change temperature. (This is the minimum temperature
required for a clean and filter to begin.) (Default is 300F (149C)). Press .
Use numbered keys to adjust CHANGE FILTER PAPER prompt. (This is the amount
of time in hours after the filter paper has been changed before the next prompt will
occur.) (The default is set to 25 hours.) If the value = 0, the CHANGE FILTER
PAPER prompt is disabled. Press .
If installed, see section 3.1 in Chapter 3.
Press the Exit/Scan button once to return the controller to OFF.
Press  until the controller scrolls INFO MODE, changing to MAIN and then
PRODUCT SETUP.
Press  to scroll to Vat Setup. Press .
Enter 1656.
Press  to scroll to E-LOG.
Press . (This is a log of the ten most recent error codes.)
Press . (Current time and date)
Errors listed A-J. Press  to scroll through errors. Error codes are listed on page 2-4.
If no errors exist, pressing  will display No errors. Press .
Press the Exit/Scan button three times to return the controller to OFF.
Press  until the controller scrolls INFO MODE, changing to MAIN and then
PRODUCT SETUP.
Press  to scroll to Vat Setup. Press .
Enter 1656.
Press  to scroll to Change Password.
Press .
Use numbered keys to change code. Press .
Use numbered keys to change code. Press .
Press the Exit/Scan button three times to return the controller to OFF.