Removing The Blade Server From The Bladecenter Unit - Lenovo BladeCenter HS22 Installation And User Manual

Machine types: 7870, 1936, 1911
Hide thumbs Also See for BladeCenter HS22:
Table of Contents

Advertisement

• Remove the device from its package and install it directly into the blade server without setting down the
device. If it is necessary to set down the device, put it back into its static-protective package. Do not
place the device on the blade server cover or on a metal surface.
• Take additional care when you handle devices during cold weather. Heating reduces indoor humidity
and increases static electricity.

Removing the blade server from the BladeCenter unit

Use these instructions to remove the blade server from the BladeCenter unit.
The following illustration shows how to remove a single-width type of blade server or blade filler from a Type
8677 BladeCenter unit. The appearance of your BladeCenter unit might be different; see the documentation
for your BladeCenter unit for additional information.
Attention:
• To maintain proper system cooling, do not operate the BladeCenter unit without a blade server, expansion
unit, or filler module installed in each blade server bay.
• When you remove the blade server, note the blade-server bay number. Reinstalling a blade server into a
different blade server bay from the one it was removed from can have unintended consequences. Some
configuration information and update options are established according to blade-server bay number; if
you reinstall the blade server into a different bay, you might have to reconfigure the blade server.
To remove the blade server, complete the following steps:
Step 1.
If the blade server is operating, shut down the operating system (see the documentation for your
operating system for more information).
Step 2.
If the server is still on, press the power-control button for four seconds to turn off the blade server
(see "Turning off the blade server" on page 14 for more information).
Attention: Wait at least 30 seconds, until the storage devices stops spinning, before you proceed
to the next step.
Step 3.
Open the two release handles as shown in the illustration. The blade server moves out of the blade
server bay approximately 0.6 cm (0.25 inch).
Step 4.
Pull the blade server out of the bay.
Attention: Two people are required to remove a Type 1911 blade server out of the bay.
Statement 4: (for Type 1911)
.
Chapter 3
Installing options
19

Advertisement

Table of Contents
loading

Table of Contents