Remove External Governor Components; Remove Oil Fill/Dipstick Tube; Remove Oil Sentry Pressure Switch; Remove Wiring Harness - Kohler KS530 Service Manual

5400 series
Hide thumbs Also See for KS530:
Table of Contents

Advertisement

Remove External Governor Components

A
Speed Control
A
Bracket
1. Mark mounted position of speed control bracket in
slotted holes and remove screws securing speed
control bracket to closure plate. Note or mark
governor spring hole for correct installation later and
unhook governor spring. Remove screws securing
speed control bracket to closure plate. Remove
control bracket.
2. Loosen nut and remove governor lever, bolt, lock
washer, and nut from governor cross shaft.

Remove Oil Fill/Dipstick Tube

Remove screw securing tube to closure plate. Lift tube
from closure plate.
Remove Oil Sentry
Pressure Switch (if equipped)
NOTE: Pressure switch is installed into closure plate.
1. Cut wire tie securing lead to switch.
2. Disconnect lead or remove connector from Oil
Sentry
pressure switch.
3. Remove pressure switch from closure plate.
Remove Rectifi er-Regulator
A
A
Rectifi er-Regulator
1. Remove screws securing rectifi er-regulator to
crankcase. Remove rectifi er-regulator.
2. Unplug connector from rectifi er-regulator.
22 690 01 Rev. --
B
B
B
Screw
B
B
Connector
KohlerEngines.com
Disassembly/Inspection and Service
Remove Ignition Module
A
B
C
A
Screw
C
Tab Terminal
1. Disconnect white lead wire from ignition module tab
terminal.
2. Rotate fl ywheel magnet away from module.
3. Remove screws and ignition module.

Remove Wiring Harness

1. Remove purple B+ wire from center of rectifi er-
regulator connector.
2. Remove cylinder head baffl e screw securing ground
wire of wiring harness.
3. Carefully remove both wire ties securing harness to
closure plate. Starter side from below closure plate;
above closure plate by cylinder head.
B
Ignition Module