Visonic SD-304C PG2 Installation Instructions Manual

Visonic SD-304C PG2 Installation Instructions Manual

Powerg, wireless shock and contact detector with wired input

Advertisement

Quick Links

SD-304C PG2
PowerG, Wireless Shock and Contact detector with Wired Input
1. INTRODUCTION
The SD- 304C PG2 is a wireless PowerG innovative shock detector with optional magnetic contact and auxiliary input interfacing with all PowerMaster
control panels, version 16 or higher. The SD-304C PG2 fits windows, doors, walls or roofs and is ideal for residential or commercial installations. It
detects and analyzes gross attacks or a series of low level shocks and provides early warning of any attempt of intrusion before a burglar actually breaks-
in.
The detector incorporates:
A shock / vibration piezoelectric sensor.
l
Optional reed switch (with optional anti-mask sensor to prevent attempts at disabling it with an extra magnet).
l
Optional auxiliary input to use with installer supplied contacts or other wired devices.
l
Installer added-value features:
Digital display enables fast and easy shock level adjustment
l
Full remote configuration from PowerMaster control panel or Monitoring Station saves the need to physically
l
access the shock detector for configuration
Remote view of: Low Battery, front and back Tamper, Supervision
l
An LED lights whenever alarm or tamper events are reported (the LED does not light while a supervision message is being transmitted).
l
2. INSTALLATION
2.1. Mounting
Refer to the Shock Detection Radius, in the Specifications section, according to the surface material used. Install the device in a location where a strong
shock impact is expected. The unit should be mounted on a flat surface and firmly fixed using both mounting screws.
For magnetic contact detection, it is highly recommended to attach the detector to the door or window on the fixed frame and the magnet to the movable
part (door or window). For optimal magnetic sensor activity and better security it is recommended to apply the magnet as close as possible to the
detector's marked side.
Note: Once the cover is removed, a tamper message is transmitted to the control panel. Subsequent removal of the battery prevents transmission of
"TAMPER RESTORE", leaving the detector in permanent alert. To avoid this, press the tamper switch while you remove the battery.
Caution! Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according to manufacturer's instructions.
Attention! The unit has a back tamper switch (optional) under the PCB. As long as the PCB is seated firmly within the base, the switch lever will be
pressed against a special break-away base segment that is loosely connected to the base ("Figure 2. Base with P.C. Board Removed" above). Be sure
to fasten the break-away segment to the wall. If the detector unit is forcibly removed from the wall, this segment will break away from the base,
causing the tamper switch to open.
D-304286 SD-304C PG2 Installation Instructions
Figure 2. Base with P.C. Board Removed
Installation Instructions
A. Transmission LED
B. Magnet
Figure 1. External View
A. Auxiliary input terminals
B. Back tamper switch
(behind P.C. board)
C. Battery clips
D. Break-away segment (for
back tamper
E. Digital display
F. Front tamper switch
G. Enroll button
H. LEDs indication
I. Reed switch
J. Up and down buttons
1

Advertisement

Table of Contents
loading

Summary of Contents for Visonic SD-304C PG2

  • Page 1 The SD- 304C PG2 is a wireless PowerG innovative shock detector with optional magnetic contact and auxiliary input interfacing with all PowerMaster control panels, version 16 or higher. The SD-304C PG2 fits windows, doors, walls or roofs and is ideal for residential or commercial installations. It...
  • Page 2: Auxiliary Input Wiring

    Note: Maximal guaranteed cable length is 10m (33 ft.). B. If the auxiliary input of the SD-304C PG2 is defined as a Normally Closed (N.C.) type, series connected N.C. sensor contacts must be used exclusively. An alarm message is transmitted once the loop is opened.
  • Page 3 2.5. Local Operating and Calibrating of the Shock Detector The SD-304C PG2 can be calibrated locally only when the device is in Local Diagnostics mode that is the first 15 minutes after opening the cover. When the device is not in this mode, but further calibration is required, the installer should reset the device by closing the tamper switch.
  • Page 4: Local Diagnostics Test

    3. While the SD-304C PG2 threshold menu is active, knock on the surface with the required force for the detector to set the required threshold. The power of the detected knock is presented on the display of the SD-304C PG2 as a blinking number for 3 seconds. The displayed number will be in the range of 1 to 19, where 1 is very weak and 19 is very strong.
  • Page 5: Miscellaneous Comments

    5. MISCELLANEOUS COMMENTS Visonic Ltd. wireless systems are very reliable and are tested to high standards. However, due to low transmitting power and limited range (required by FCC and other regulatory authorities), there are some limitations to be considered: A. Receivers may be blocked by radio signals occurring on or near their operating frequencies, regardless of the digital code used.
  • Page 6: Appendix: Specifications

    The antennas used for this product must not be co- located or operated in conjunction with any other antenna or transmitter. Warning! The user is cautioned that changes or modifications to the unit, not expressly approved by Visonic Ltd., could void the user’s FCC or other authority to operate the equipment.
  • Page 7: Warranty

    WARRANTY Visonic Limited (the “Manufacturer") warrants this product only (the "Product") to the original purchaser only (the “Purchaser”) against defective workmanship and materials under normal use of the Product for a period of twelve (12) months from the date of shipment by the Manufacturer.
  • Page 8 * In case of a conflict, contradiction or interpretation between the English version of the warranty and other versions, the English version shall prevail. Email: info@visonic.com Internet: www.visonic.com © VISONIC LTD. 2017 SD-304C PG2 D-304286 (Rev. 9 08/17) D-304286 SD-304C PG2 Installation Instructions...

Table of Contents