5. Connection Procedure

The procedure for connecting the M3T-FLX-100NSE is
shown below.
(1) Mount the NQPACK100SE on the target system.
(2) Attach the YQPACK100SE on the NQPACK100SE.
(3) Secure the four corners of the YQPACK100SE with the
YQ-GUIDE's.
• Do NOT use the screws included with the
YQPACK100SE.
• Do NOT use the screwdriver included with the
NQPACK100SE that is used only for the
HQPACK100SE. It is not for the YQ-GUIDE's.
(4) Attach the M3T-FLX-100NSE on the YQPACK100SE.
(5) Attach the probe of the emulation pod to the M3T-FLX-
100NSE.
6. External Dimensions and a Sample Foot Pattern
Figure 4 External dimensions and a sample foot pattern
(See Figure 3)
Figure 3 Connection procedure
( 3 / 4 )
M3T-FLX-100NSE
YQ-GUIDE's (x4)
YQPACK100SE
NQPACK100SE
100-pin 0.4-mm-pitch
(100PFB-A) foot pattern
FLX100
Use a slotted screwdriver.
: Position of No. 1 pin
Be sure to align the pins.
Unit: mm