5. Connection Procedure

The procedure for connecting the M3T-FLX-100NSD is shown
below.
(1) Mount the NQPACK100SD-ND on the user system.
(2) Attach the YQPACK100SD on the NQPACK100SD-ND.
(3) Secure the four corners of the YQPACK100SD with the
YQ-GUIDE's.
● Do not use the screws included with the
YQPACK100SD for fixing the YQPACK100SD.
● Do NOT used the screwdriver included with the
NQPACK100SD-ND that is used only for the
HQPACK100SD.
(4) Attach the M3T-FLX-100NSD on the YQPACK100SD.
(5) Attach the probe of the emulation pod to the M3T-FLX-
100NSD.
6. External Dimensions and a Sample Foot Pattern
27.0
M3T-FLX-100NSD
50
26
J1
25
1
50
26
J2
1
25
REV.A JAPAN
Figure 4 External dimensions and a sample foot pattern of the M3T-FLX-100NSD
(See Figure 3)
28.6
(3/4)
M3T-FLX-100NSD
YQ-GUIDE (x4)
YQPACK100SD
NQPACK100SD-ND
100-pin 0.5-mm-pitch
(100P6Q-A) foot pattern
Figure 3 Connection procedure of the M3T-FLX-100NSD
0.25
0.5
13.0
17.0
FLX100
(5)
(4)
Use a slotted screwdriver.
(3)
(2)
(1)
: No. 1 pin
Be sure to align the pins.
Unit: mm