5. Connection Procedure

The procedure for connecting the M3T-F160-100NRB is
shown below.
(1) Mount the NQPACK100RB on the user system.
(2) Attach the YQPACK100RB on the NQPACK100RB.
(3) Secure the four corners of the YQPACK100RB with the
YQ-GUIDE's.
● Do not use the screws included with the
YQPACK100RB for fixing the YQPACK100RB.
● Do NOT use the screwdriver included with the
NQPACK100RB for fixing the YQ-GUIDE's. That is
used only for the HQPACK100RB168 or
HQPACK100RB1622.
(4) Attach the probe of the emulation pod to the M3T-
F160-100NRB.
(5) Connect M3T-F160-100NRB to the emulator probe.
6. External Dimensions and a Sample Foot Pattern
55.0
80
81
100
●1
IC1
M3T-F160-100NRB REV.A
MADE IN JAPAN
Figure 4 External dimensions and a sample foot pattern of the M3T-F160-100NRB
(See Figure 3)
21.8
51
50
31
30
M3T-F160-100NRB
YQ-GUIDE -1
YQPACK100RB
NQPACK100RB
100-pin 0.65-mm-pitch
(PRQP0100JB-A,
formerly 100P6S-A) foot pattern
: No.1 pin
Be sure to align the pins.
Figure 3 Connection procedure of the M3T-F160-100NRB
(3/4)
FLX160-PRB,
M3xxxxTx-EPB
or
M3xxxxTx-CPE
(5)
(4)
Use a slotted screwdriver.
(3)
(2)
(1)
0.35
0.65
13.8
17.2
Unit: mm