Mitsubishi Electric MR-J2-03B5 Instruction Manual page 50

General-purpose ac servo, sscnet compatible, melservo-j2/jr series, servo amplifier
Table of Contents

Advertisement

4. OPERATION AND DISPLAY
(2) Indication list
Indication
AA
Initializing
Ab
Initializing
AC
Initializing
Ad
Initializing
AE
Initialize completion
b#
Ready OFF
(Note 1)
d#
Servo ON
(Note 1)
C#
Servo OFF
(Note 1)
**
Alarm Warning
(Note 2)
88
CPU error
b0.
(Note 3)
b#.
(Note 1)
Test operation mode
d#.
c#.
Note: 1. # denotes any of numerals 0 to 8 and what it means is listed below:
#
Description
0
Set to the test operation mode.
1
First axis
2
Second axis
3
Third axis
4
Fourth axis
5
Fifth axis
6
Sixth axis
7
Seventh axis
8
Eighth axis
2. ** indicates the warning/alarm No.
3. Requires the servo configuration software.
Status
The servo amplifier was switched on when power to the servo system
controller is off.
Power to the servo system controller was switched off during power-on of
the servo amplifier.
The axis No. set to the servo system controller does not match the axis No.
set with the axis setting switch (CS1) of the servo amplifier.
A servo amplifier fault occurred or an error took place in communication
with the servo system controller. In this case, the indication changes:
"Ab"
The servo system controller is faulty.
Communication started between the servo system controller and servo
amplifier.
The initial parameters from the servo system controller were received.
Initial data communication with the servo system controller was completed.
The ready off signal from the servo system controller was received.
The ready off signal from the servo system controller was received.
The ready off signal from the servo system controller was received.
The alarm No./warning No. that occurred is displayed. (Refer to Section 8.1.)
JOG operation, positioning operation, programmed operation, DO forced
output.
Motor-less operation
Description
"AC"
"Ad"
"Ab"
4 - 5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents