Midea HP170 Installation & Maintenance Manual

Midea HP170 Installation & Maintenance Manual

Heat pump water heater 170 litre
Hide thumbs Also See for HP170:

Advertisement

Installation &
Maintenance Guide
Midea Heat Pump Water Heater - 170 Litre
Page i

Advertisement

Table of Contents
loading

Summary of Contents for Midea HP170

  • Page 1 Installation & Maintenance Guide Midea Heat Pump Water Heater - 170 Litre Page i...
  • Page 2 If you can’t ensure that the property's power supply is correctly earthed, please don’t WARNING install the unit. The unit must be installed by a licensed trade person and in accordance with: This unit requires reliable earthing before usage, • This Installation & Maintenance Guide. otherwise this may result in injury or death.
  • Page 3: Table Of Contents

    GUIDE CONTENTS Section 1: Product Information & Schematics Section 2: Safety Information Section 3: Before Installation Section 4: System Installation 9-10 Section 5: System Commissioning 11-14 Section 6: System Operation 15-17 Section 7: System Troubleshooting Section 8: System Maintenance Section 9: Warranty...
  • Page 4: Product Information & Schematics

    PRODUCT INFORMATION & SCHEMATICS 1.1 System Schematics (Dimensions in millimetres) 568 (WIDTH) MIN 700 MIN 700 (SUPPORT BASE) (SUPPORT BASE) 1.2 System Parts POWER CONNECT BOX & COVER TOP COVER COMPRESSOR ELECTRONIC CONTROL BOX FAN ASSEMBLY UPPER FRONT COVER UPPER REAR COVER DISPLAY EVAPORATOR FILTER ANODE ROD COVER...
  • Page 5 1.3 System Specifications Model HP170 (RSJ-15/190RDN3-C) Modes Economy Hybrid E-Heater Heat Pump E-Heater Hot water heating capacity 1500W 2150W 1500W 2150W Rated input power/current 780W/3.4A 2780W/12.1A 2150W/9.3A Power supply 220-240V~ 50Hz Protection Over-load Protector, Temp Controller & Protector, Electric Leakage Protector...
  • Page 6: Safety Information

    SAFETY INFORMATION Please read thoroughly all of the instructions before installing and operating the unit. The following safety warnings are very important, always read and obey all safety symbols: WARNING CAUTION • The unit must be earthed effectively. • The earthing pole must be well grounded. Make sure that any power supply socket and plug are dry and connected tightly.
  • Page 7: Before Installation

    BEFORE INSTALLATION 3.1 Unpacking CAUTION When unpacking ensure the following items are included: • Consideration must also be made in regards to the ambient air Main Unit temperature. Heat pump economy mode operates between The Main unit including the storage tank & heat pump ambient air temperatures of 5°C and 43°C.
  • Page 8: System Installation

    SYSTEM INSTALLATION 4.1 Plumbing Layout 4.2 Installation position requirement Install the unit with suitable clearance for air flow and plumbing access (refer to options below) CONDENSATE OUTLET (UPPER) OPTION 1 (Front On) CONDENSATE WALL OUTLET (LOWER) AIR OUTLET PTR VALVE HOT WATER TEMPERING OUTLET...
  • Page 9: Plumbing Connections

    (INC. NO RETUR HOT PIPE HOT PIPE (TO TEMP VALVE (TO TEMP VALVE) VALVE) COLD PIPE (INC. NON COLD PIPE RETURN (INC. NON 4.3 Plumbing Connections 4.4 Electric Connection VALVE) RETURN COLD PIPE VALVE) Remove the top cover by releasing the locking screw and rotating 4.3.1 Condensation draining tube (INC.
  • Page 10: Installation Checklist

    4.4 Protective Covers 4.5 Installation checklist 4.4.1 Fascia Cover 4.5.1 Location Fit the fascia cover using the locating pins at the top & the locking … The flooring beneath the water heater is able to support the bracket at the lower position. weight of the water heater when filled.
  • Page 11 4.6 Final Installation Below is an example of a proper heat pump installation along with all plumbing and electrical connections. Page 8...
  • Page 12: System Commissioning

    SYSTEM COMMISSIONING 5.1 Filling tank before operation 5.3 About Running This heat pump unit has two kinds of heat sources: CAUTION Heat Pump (compressor) and Electric heater (element). The unit will automatically select the heat source/s to heat the Operation without water in the stored water to the target temperature depending on the mode tank may result in the damage of selected and the surrounding conditions.
  • Page 13 5.4 Setting the mode 5.5 Automatic functions Operating mode should be selected manually. 5.5.1 Defrosting during water-heating Refer to the below table for the modes of operation and the running temperature ranges & temperature limits: • During the heat pump running period, if the evaporator becomes frosted due to low ambient temperatures, the Operation Ambient...
  • Page 14: System Operation

    SYSTEM OPERATION 6.1 Display Screen ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ Ambient temperature outside the operational range of the heat pump: If the ambient temperature is outside the operating range of the heat pump function, the LA icon will be displayed on screen Wired controller (reserved function): If a wired controller is connected to the unit then the Wired Controller icon will be displayed on screen...
  • Page 15: Water Temperature Setting

    Lock: If the control panel is in a locked state, the Lock icon will be displayed on screen Economy mode: If the unit is operating in economy mode, the Economy Mode icon will be displayed on screen. When selecting mode, the icon will flash if economy mode is selected. Hybrid mode: If the unit is operating in hybrid mode, the Hybrid Mode icon will be displayed on screen.
  • Page 16: Control Panel

    6.2 Control Panel Before performing any functions on the control panel it needs to be unlocked. To unlock the control panel, press & hold the CANCEL button for 3 seconds. The controller screen can be illuminated by pressing any button. An illuminated screen does not mean the control panel is unlocked or that the unit is running.
  • Page 17 Setting the TIME ON Timer If the Timer is set to TIME ON, the unit will automatically operate once between the setting of the clock and the last 24 hours. • To set the TIME ON value, unlock the control panel and proceed to press the TIME ON button. The TIME ON clock will appear below the normal clock with the hour value flashing •...
  • Page 18: System Troubleshooting

    SYSTEM TROUBLESHOOTING 7.1 General Troubleshooting The unit has been switched off. 7.1.1 How do I know the unit is working Check the unit and ensure the red LED light is showing. If Check that the LED light next to the on/off button is on. If this light not, unlock the controller by holding the cancel button for is not lit, then the system is not operating.
  • Page 19 7.1.6 Unit is outside a bedroom & the noise is too 7.1.3 It appears water is leaking from the unit. much during the night The unit is fitted with a condensate release point at the lower section of the head unit towards the rear of the system. At If the location of your heat pump unit is in close proximity to time of installation a condensate drain pipe should have been a bedroom and your hot water usage pattern is consistently...
  • Page 20: Error Codes

    7.2 Error Codes Display Malfunction Description Corrective Action The connection between sensor and PCB is broken or the Error of sensor T5L (lower water temperature sensor) sensor has experienced an issue. Contact a qualified person to service the unit. The connection between controller and PCB is broken or the Tank and wired controller communication error PCB has experienced an issue.
  • Page 21: System Maintenance

    SYSTEM MAINTENANCE 8.1 Cleaning the air filter 8.3 Cleaning the inner tank and E-Heater (Frequency: Every Month) (Frequency: Every Half Year) • Turn off the power to the unit. It is recommended to clean the inner tank and E-Heater regularly to maintain efficient performance.
  • Page 22: Warranty

    WARRANTY The warranty applies to Midea heat pumps installed in a single family dwelling only and is provided only to those acquiring the heat pump as consumers within the meaning of the Australian Consumer Law. The terms of the warranty are effective from the date the heat pump is installed.
  • Page 23: Warranty Registration

    Notes: Images shown are representative only. Product specifications subject to change without notice. For the latest product details and specifications, please visit our website - www.chromagen.com.au. Chromagen Australia source a range of high quality products & components from a global marketplace to provide Australian consumers with outstanding energy efficient and value for money solutions for their home. Warranty Registration (see reverse side for further instruction) Please provide the following details...
  • Page 24 Another Hot Water Solution by chromagen.com.au | 1300 367 565 Hot Water Solutions | Solar Power Systems | Kitchen Appliances | Air Conditioning Warranty Registration To register your warranty please ensure to fill out the back of this page. Cut along dotted line and place in an envelope and address as follows: Chromagen Australia Pty Ltd 17-23 Redwood Drive, Dingley Village VIC 3172...

This manual is also suitable for:

Rsj-15/190rdn3-c

Table of Contents