Portable Air-conditioner Use and Care Manual Part Number: 048-GM-48334 Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before installing and using this appliance. Please keep this Use and Care Manual properly for...
Safety Instructions 1. Electrical Specifications 1. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding to the following instructions, please contact a qualified electrician. 2. The unit must be installed in accordance with national wiring regulations. Check available power supply and resolve any wiring problems before installation and operation of this unit.
Page 4
3. Cautions ※ Keep the unit at least 1 meter away from TV or radios to avoid electromagnetic interference. ※ Do not expose the unit under direct sun light to avoid surface color fading. ※ Do not tilt the unit for more than 35 degrees or upside-down while transporting. ※...
Function and Technical Specification ※ This unit offers cooling, dry, fan and sleep modes, ideal for home and office use. ※ This unit is with two fan-speed level accessible by panel control and remote control. Temperature setting range of this unit is 62.6-86 ℉ (17-30℃).. ※...
Identification of Parts 1. Control panel 16. Lower drain hole and plug 2. Vertical louvers 17. Handle 3. Horizontal louvers 18. Air discharge and protective vent 4. Horizontal louvers connecting rod 19. Chassis 5. Air outlet frame 20. Remote control 6.
Operation and Settings This section explains proper mobile air conditioner operation. 1. Control Panel On/Off button Up button Mode button Timer button Down button Fan speed button Fan speed Timer indicator Water-full indicator indicator Fan mode Cool mode Dehumidify mode indicator indicator Remote control signal Sleep mode indicator...
Page 8
The temperature can be set within a range of 62.6-86℉(17-30℃) under cooling mode. Press+ or- buttons to increase or decrease the temperature 1.8℉(1℃) by pressing once. Press+ and -buttons together to convert Celsius degrees and Fahrenheit degrees and corresponding indicator will light up.
Page 9
3. Remote Control Operation The Remote control transmits the signal to system. Button: press this button to start unit when it is energized or stop the unit when it is in operation. Button: press this button to set unit automatic on and off time Button: press this button to select high speed of fan running (except dry and sleep modes) Button: press this button to select low speed of fan running.
control if the batteries have any leakage. If you eat the liquid from the batteries, brush your teeth and see doctor. The chemicals in batteries could cause burns or other health hazards. Multiple Protection Functions 1. Anti-freeze protection function Compressor, water spraying motor will turn off when compressors running over 10 minutes and tube temperature (Tp) is continuously ≦35.6℉(2℃)...
Installation & Adjustment 1. Installation Warning: Keep this mobile air-conditioner in upright position at least 2 hours before first installation. This air-conditioner may be moved indoors conveniently; keep the unit in upright position while moving it. The air-conditioner shall be placed on flat surface. ...
Page 12
Hold the unit by one hand, carry the exhaust hose assembly with another hand and push it into unit gently, for good lock of two parts. (as Photo) Remarks: Keep the right direction of slant side A of adapter, for ease installation of window seal-plate. ...
Install the rectangle end of exhaust hose adapter into the corresponding rectangle hole in window seal-plate assembly, fix it with screw and close the window (as Photo). Align the 4 openings on window seal-plate with corresponding 4 openings on exhaust hose adapter and set them together, then slide adapter downwards, to make 2 set of openings locked for 2 parts good connection.
Page 14
working, both water-full indicator and “FL” is flashing on LED display window. Put the tray below the water outlet at the back of the unit. Screw off the drain cover, unplug the water stopper for water flow into the tray. Plug in stopper and screw the water cover tightly onto water outlet after drainage.
Drain cap Maintenance and Service Remark: Turn off the unit and pull out the plug before maintain or send the unit to service center. 1. Surface cleaning Clean the unit surface with wet and soft cloth, but do not use chemical solvents such as alcohol and gasoline to avoid any damage to unit.
5. Pack the air-conditioner properly with soft plastic bag and put it in dry place with appropriate dust-proof measures and keep the unit away from children. 6. Take out the batteries from the remote control and keep unit in a try place, including all accessories well. Troubleshooting Please check the unit and suggestions below before asking for professional service, but never dismantle or repair the unit by yourself, it may cause harm to you and your property.
displays error Check the room temperature sensor Room temperature sensor failure code “E2” and related circuits displays error Restore the functions automatically Anti-freeze protection code “E4” once anti-freeze protection is over. Water-full indicator The water in chassis is full Drain the water and re-start the unit lights Appendix Fuse parameters...
Page 18
(1) year from the date of purchase. 7 Dissatisfaction due to buyer’s remorse. In no event shall DELLA be liable for indirect, con- 8 Normal wear and tear. sequential or incidental damages of any kind.
Page 19
**WARNING: READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE. www.dellaproductsusa.com 909. 344. 2588...
Need help?
Do you have a question about the 048-GM-48334 and is the answer not in the manual?