OPERATION
4
Parameter
Parameter
Parameter
Parameter
DD name
FF_SCALE
FF_SCALE
FF_SCALE
FF_SCALE
Feed Forward Scale
Feed Forward Scale
Feed Forward Scale
Feed Forward Scale
EU_100
EU at 100%
EU_0
EU at 0%
UNITS_INDEX
Units Index
FF_VAL
FF_VAL
FF_VAL
FF_VAL
Feed Forward Value
Feed Forward Value
Feed Forward Value
Feed Forward Value
STATUS
Status
VALUE
Value
GAIN
GAIN
GAIN
GAIN
Gain
Gain
Gain
Gain
GRANT_DENY
GRANT_DENY
GRANT_DENY
GRANT_DENY
Grant Deny
Grant Deny
Grant Deny
Grant Deny
GRANT
Grant
DENY
Deny
HI_ALM
HI_ALM
HI_ALM
HI_ALM
High Alarm
High Alarm
High Alarm
High Alarm
UNACKNOWLEDGED
Unacknowledged
52
Access
Description and settings
R/W
The feed forward input high and low scale values, engineering
units code and number of digits to the right of the decimal
point.
R/W
The engineering unit value which represents the upper end of
range of the associated block parameter.
R/W
The engineering unit value which represents the lower end of
range of the associated block parameter.
R/W
Device Description units code index for the engineering unit
descriptor for the associated block value.
Setting:
All units are possible.
R
The feed forward value and status.
R
Status of FF_VAL
R
Value of FF_VAL
R/W
Dimensionless value used by the block algorithm in
calculating the block output.
R/W
Options for controlling access of host computers and local
control panels to operating, tuning and alarm parameters of
the block.
R/W
Depending on the philosophy of the plant, the operator or a
higher level device (HLD), or a local operator's panel (LOP) in
the case of Local, may turn on an item of the Grant attribute -
Program, Tuning, Alarm or Local.
Setting:
Program: Host may change mode, setpoint or output of block
Tune: Host may change the tuning parameters of block
Alarm: Host may change the alarm parameters of block
Local: A local panel or handheld device may change the
target mode, setpoint or output
R/W
The "Denied" attribute is provided for use by a monitoring
application in an interface device and may not be changed by
an operator.
Setting:
Program denied: Granting of program permission has been
reset
Tune denied: Granting of tune permission has been reset
Alarm denied: Granting of alarm permission has been reset
Local denied: Granting of local permission has been reset
Mix
The status for High Alarm and its associated time stamp.
R/W
A discrete enumeration which is set to "Unacknowledged"
when an alarm occurs, and set to "Acknowledged" by a write
from a human interface device or other entity which can
acknowledge that the alarm/event has been noticed.
Setting:
Uninitialized / Acknowledged / Unacknowledged
www.honeywellprocess.com
TWM 9000
Initial Value
-
100
0
Uninitialized
-
-
-
0
-
No option selected
No option selected
-
Uninitialized
34-VF-25-37 iss.2 GLO Jan 18 US