TWM 9000
Parameter
Parameter
Parameter
Parameter
Subelement
NORMAL
Normal
ST_REV
ST_REV
ST_REV
ST_REV
Static Revision
Static Revision
Static Revision
Static Revision
STRATEGY
STRATEGY
STRATEGY
STRATEGY
Strategy
Strategy
Strategy
Strategy
TAG_DESC
TAG_DESC
TAG_DESC
TAG_DESC
Tag Description
Tag Description
Tag Description
Tag Description
ACK_OPTION
ACK_OPTION
ACK_OPTION
ACK_OPTION
Acknowledge Option
Acknowledge Option
Acknowledge Option
Acknowledge Option
ALARM_SUM
ALARM_SUM
ALARM_SUM
ALARM_SUM
Alarm Summary
Alarm Summary
Alarm Summary
Alarm Summary
Current
Unacknowledged
Unreported
Disabled
BLOCK_ALM
BLOCK_ALM
BLOCK_ALM
BLOCK_ALM
Block Alarm
Block Alarm
Block Alarm
Block Alarm
Unacknowledged
Alarm State
34-VF-25-37 iss.2 GLO Jan 18 US
Access
Description and settings
R/W
This is the mode which the block should be set to during
normal operating conditions.
Setting:
Auto / OOS
R
The revision level of the static data associated with the
function block. The revision value will be incremented each
time a static parameter value in the block is changed.
Setting:
0...65535
R/W
The strategy field can be used to identify grouping of blocks.
This data is not checked or processed by the block.
Setting:
0...65535
R/W
The user description of the intended application of the block.
Setting:
≤32 digits
R/W
Selection of whether alarms associated with the function
block will be automatically acknowledged.
Setting:
Disc Alm Disabled / Block Alm Disabled
R
The current alert status, unacknowledged states, unreported
states and disabled states of the alarms associated with the
function block.
R
The active status of each alarm. The zero (0) state will be used
to indicate alarm clear.
R
Setting:
Disc Alm Unack / Block Alm Unack
R
Setting:
Disc Alm Unrep / Block Alm Unrep
R/W
Setting:
Disc Alm Disabled / Block Alm Disabled
Mix
The block alarm is used for all configuration, hardware,
connection failure or system problems in the block. The cause
of the alert is entered in the subcode field. The first alert to
become active will set the "Active" status in the "Status"
attribute. As soon as the "Unreported" status is cleared by the
alert reporting task, another block alert may be reported
without clearing the "Active" status, if the subcode has
changed.
R/W
A discrete enumeration which is set to "Unacknowledged"
when an alarm occurs, and set to "Acknowledged" by a write
from a human interface device or other entity which can
acknowledge that the alarm/event has been noticed.
Setting:
Uninitialized / Acknowledged / Unacknowledged
R
A discrete enumeration which gives an indication of whether
the alert is active and whether it has been reported.
Setting:
Uninitialized / Clear - reported / Clear - not reported / Active -
reported / Active - not reported
www.honeywellprocess.com
OPERATION
4
Initial Value
Auto
0
0 (=uninitialized)
spaces
Uninitialized
Uninitialized
0
Uninitialized
Uninitialized
Uninitialized
-
Uninitialized
Uninitialized
15