8.3 IR Thermometer Specifications
IR Temp. Measurement range
Over‐ and under‐ range indication OL
IR Temperature Resolution
IR Temperature Accuracy
Distance to Spot (D:S) ratio
Field of view angle
IR Temperature Response Time
Temperature Scanning
Emissivity
8.4 Laser Specifications
Laser type
Laser wavelength
Laser power
Laser alignment
8.5 Thermocouple Specifications
Thermocouple type
Meter input range*
Meter input accuracy
Measurement resolution
*Included Type K probe range
FLIR TG54_TG56 User Manual
‐22°F ~ +1202°F (‐30°C ~ +650°C)
0.1°C (0.1°F up to 999
‐22° ~ +14°F (‐30° ~ ‐10°C): ±5.4°F (3.0°C)
+14° ~ +32°F (‐10° ~ < 0°C): ±3.6°F (2.0°C)
+32° ~ +1202°F (0° ~ +650°C): ±1.8°F (±1.0°C) or ±1.0%
(whichever is greater)
24:1 for TG54
30:1 for TG56
o
0.04
150ms
Continuous
4 presets plus a custom setting (0.10 ~ 0.99)
Single Class 1 Laser (red; visible light)
650nm ±20nm
≤0.39 mW
Parallel to measurement 'cone'; see Section 5.3, Distance
to Spot Ratio
Type K
‐22° to 1202°F (‐30° to 650°C)
±3.6°F (2°C) or ±1% whichever is greater
Not including additional probe error: ±4.5°F (2.5°C)
0.1°C (0.1°F up to 999
‐22° to 572°F (‐30° to 300°C)
23
Document Identifier: TG54_TG56‐en‐US_AA
o
o
F and 1
F when ≥ 1000
o
o
F and 1
F when ≥ 1000
o
F)
o
F)