Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
GREEN SERIES FITNESS Manuals
Treadmill
CIR-TM6000DC-G
Service manual
GREEN SERIES FITNESS CIR-TM6000DC-G Service Manual
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
page
of
14
Go
/
14
Contents
Table of Contents
Bookmarks
Table of Contents
Service Manual
Table of Contents
1 Information for Components & System
System Wiring Diagram
Motor Driver
Console PCB
2 Error Signal Check and Solutions
S Peed Errore
3 Other Information
Console no Power, no Display
4 Engineering Mode
Engineering Mode ONE: Basic Settings
Engineering Mode TWO: Used Information Management
5 Program Update
Install Software from PC
Programmer Update
Product Update
Advertisement
Quick Links
1
Service Manual
2
System Wiring Diagram
3
Error Signal Check and Solutions
Download this manual
SERVICE MANUAL
PRODUCT:
TREADMILL: CIR-TM6000DC-G
www.GreenSeriesFitness.com
©May 2015
Call Toll free (800) 269-7140
CIR-TM6000DC-G Revision 1.1
1
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the CIR-TM6000DC-G and is the answer not in the manual?
Ask a question
Questions and answers
Subscribe to Our Youtube Channel
Related Manuals for GREEN SERIES FITNESS CIR-TM6000DC-G
Treadmill GREEN SERIES FITNESS CIR-TM8000E-G Owner's Manual
Full commercial treadmill (52 pages)
Treadmill GREEN SERIES FITNESS CIR-TM6000AC-G Owner's Manual
Light commercial treadmill (44 pages)
Treadmill GREEN SERIES FITNESS CIR-TM7000E-G1 Owner's Manual
Full commercial treadmill (41 pages)
Treadmill GREEN SERIES FITNESS CIR-TM8000-G Owner's Manual
Full commercial treadmill (84 pages)
Treadmill GREEN SERIES FITNESS CIR-TM7000-G Owner's Manual
Full commercial treadmill (30 pages)
Treadmill GREEN SERIES FITNESS CIR-TM7000E-G Upgrade Procedure
Suspension upgrade procedure (20 pages)
Treadmill GREEN SERIES FITNESS CIR-TM7000E-G Procedure
Elevation motor zero out procedure (3 pages)
Treadmill GREEN SERIES FITNESS CIR-TM7000-G1 Owner's Manual
Full commercial treadmill (44 pages)
Treadmill GREEN SERIES FITNESS CIR-TM6000AC-G1 Owner's Manual
(51 pages)
Treadmill GREEN SERIES FITNESS 6000 Series Programming Manualline
Elevation error reprogramming (3 pages)
Summary of Contents for GREEN SERIES FITNESS CIR-TM6000DC-G
Page 1: Service Manual
SERVICE MANUAL PRODUCT: TREADMILL: CIR-TM6000DC-G www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 2: Table Of Contents
4.7. Engineering Mode SEVEN: Low Fan Output Setting ………..…………………………………...………...… 8 5. Program Update 5.1. Install Software from PC ………...…………………..…….………………………………………...……….… 8 5.2. Programmer Update …………………..………………………………………………………………….…….. 8 5.3. Product Update …………………………………………………………………………………………………...8 www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 3: Information For Components & System
1. Information for Components & System 1.1. System Wiring Diagram : www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 4: Motor Driver
L ights up while incline motor goes down. : ( ) : D C12V power pilot lamp G reen L ights up normally while power on. : ( ) : www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 5
Motor EN Slow Fast +12V Definition of J1 (ISP / Program Updater) Connector Define Down Definition of JK2 (SAFET) Connector Define Control Definition of JK4 (RF) Connector Define Output www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 6
Definition of JK5 (HP) Connector Define Output Definition of JK7/8 (Fan) Connector Define Definition of JK9 (MP3) Connector Define www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 7: Error Signal Check And Solutions
Console PCB damaged. Motor controller defective. Replace the Replace the controller. console PCB. Speed Feedback system program. If this happens on a regular basis, Replace speed sensor. replace the console. www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 8
STOP to go back to idle state. Remark A: Before installing a new incline motor or Variable Resistor (VR), be sure to have the incline level set to zero ( 0 ). www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 9: Other Information
Replace the membrane key or the switch PCB. * The system will not allow the incline keys to function if the wires are not connected from the incline motor to the motor controller. www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 10
Is the running belt increasing pinched or cut. Refer to the Replace the or decreasing as the keys are photos in section 3.1. motor controller. pressed? Replace the speed sensor. www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 11: Engineering Mode
「 Speed Fast 」 「 S peed Slow 」 t o set the age, range: 13~80, press 「 E nter 」 t o confirm and back to idle mode. www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 12: Install Software From Pc
Open the document then open the “PC-site Driver” document. Select file 0E6A030D_8051ISPICP_v3.00 the right click and select “Install (I)”. 5.2 Programmer Update 5.2.1 Connect the programmer into the PC USB port. On the programmer, LED2 and LED3 will illuminate. www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 13: Product Update
, press OK. Update successful. 】 【 】 Load File Update Programmer Updated 5.3 Product Update 5.3.1 Turn OFF the AC power and then open the console. See below for location of screws. www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Page 14
Turn ON the AC power and then press the update button to update the program. Update button LED1 Flash LED1 Off Done 5.3.4 Please remove the programmer and reboot the system to finish the update. (reset power) www.GreenSeriesFitness.com ©May 2015 Call Toll free (800) 269-7140 CIR-TM6000DC-G Revision 1.1...
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the CIR-TM6000DC-G and is the answer not in the manual?
Questions and answers