Releasing A Trapped Auger; Cleaning The Air Filter - Stihl BT 120 C Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

English / USA
Working with Shaft Extension
(special accessory)
Do not fit the shaft extension until the full
length of the auger is in the hole.
Starting a hole with the shaft
extension fitted increases the risk of
personal injury because the unit is
then at chest height and cannot be
kept properly under control.
For the same reason the shaft
extension must be removed before
the auger is pulled out of the hole.
18

Releasing a Trapped Auger

A
If the auger jams in the drill hole - shut off
the engine immediately.
:
Move the slide control in direction of
c to $
:
Engage the auger brake by moving
the activating lever to position A.
:
Now rotate the whole machine to
the left – counterclockwise – to
unwind the auger from the ground.

Cleaning the Air Filter

1
3
2
If there is a noticeable loss of
engine power
:
Turn choke knob to g
:
Press in the tab (1).
:
Remove the filter cover (2).
:
Clean away loose dirt from inside of
filter cover and around the filter.
:
Remove the filter element (3) and
check it – if it is dirty or damaged, fit
a new element.
:
Fit the flter element in the filter
cover.
:
Push the filter cover into position.