Download Print this page

SATO CL4NX Configuration Manual page 2

Hf rfid
Hide thumbs Also See for CL4NX:

Advertisement

B) Physical Antenna Position
Adjust the physical position of the antenna according to the settings required for the specific label and inlay
used.
(b)
Blue
Blue
Blue
Yellow
Yellow
Yellow
Green
Green
Green
Rotate the dial (a) to align the pointer (b) with the label to
be used. See under "Antenna Position" in the CL4NX HF
Inlay Placement & Configuration Table in the CL4NX HF
Inlay Configuration Guide.
3 Set Labels and Carbon Ribbon.
Refer to the sticker on the printer's top cover, the help videos in the printer menu, and the Operator Manual for
more information.
4 Confirm operation by printing/encoding a label.
Be sure to read the data and check that it is correctly encoded.
RFID Printing Tips
A) Recommended no-print zone
Avoid printing barcodes or characters directly on top of an
RFID chip. The uneven surface will negatively affect print
quality.
B) Printing of RFID tag errors
The printer can be set to print an RFID tag error when there
is a problem with the recorded data, for example in a write
to a defective tag, in order to prevent accidental distribution
of a defective label. Depending on the error and the print
command paper size setting, a diagonal line or a cross will
(a)
be printed, together with a description of the error.
• List of errors printed
Message
TAG NOT FOUND
WRITE TAG ERROR
PROTECT TAG ERROR
VERIFY TAG ERR.
LOCKING ERROR
WRONG TID ERROR
MULTI TAGS ERROR
Extensive contact information for worldwide SATO operations can be found on the Internet at
www.satoworldwide.com
Recommended no-print zone
IC chip
Gap
Cause and Countermeasure
Cause
Tag cannot be found, or reading failed.
Countermeasure
Confirm inlay operation and check printer / antenna configuration.
Cause
Writing failed.
Countermeasure
Confirm inlay operation and check printer / antenna configuration.
Cause 1
An attempt was made to write to a tag with the write lock set.
Cause 2
An attempt was made to write to a non-writable address.
Countermeasure
Use a label with the lock not set.
Cause
The written value and the read value are not identical.
Countermeasure
Confirm inlay operation and check the printer/antenna
configuration.
Cause 1
Lock processing failed because the label has been locked.
Cause 2
Lock processing failed because the antenna output is weak.
Countermeasure
Check if the label was locked and if the inlay antenna placement
is correct.
Cause
A tag type other than that specified in command data was
detected.
Countermeasure
Ensure that command tag type matches actual label/tag.
Cause
Multiple tags captured simultaneously.
Countermeasure
Confirm inlay operation and check printer / antenna configuration.
Feed Direction
Antenna
inlay
15 mm
RFID tag/label
15 mm
Print object
I-Mark
Feed Direction
TAG NOT FOUND