GETTING STARTED
INSERT BATTERIES
1. Gently pull the battery compartment cover apart from the
unit.
2. Insert the batteries, matching the polarities (+/-).
3. Press RESET after each battery replacement.
Alizé Thermometer
LOCATION
Model: RMR262
User Manual
Outdoor temperature area
Indoor temperature area
EN
NOTE

OVERVIEW

the display/backlight is dim.
FRONT VIEW
REMOTE SENSOR
The main unit can collect data from up to 5 sensors.
1
To set up the sensor:
2
1. Open the battery compartment.
2. Select a channel then press RESET.
3. Close the battery door.
3
4. Place the sensor within 30 m (98 ft) of the main unit using
the table stand or wall mount.
4
TIP
Ideal placements for the sensor would be in any location
on the exterior of the home at a height of 1.5 m (5 ft) and
5
which can shield it from direct sunlight or wet conditions for
an accurate reading.
1. Ice alert indicator
2. + - Press to increase settings, press and hold to increase
settings rapidly
3.
- Press to toggle between the clock and calendar,
press and hold to enter the setting mode
4. MEM – Press to toggle the current/maximum/minimum
temperature records, press and hold to clear the MAX/
MIN records.
5. – - Press to decrease settings, press and hold to
decrease settings rapidly, Press and hold to turn off the
ice alert
TOP VIEW
1
2
3
4
5
1. SENSOR – Press to toggle between channel 1-5, turn
on or off display in loop. Press and hold to search for the
NOTE
sensor for all channels
grade lithium batteries in temperatures below freezing.
2. LIGHT – Press to turn on the backlight
3. RCC – Press to turn on and toggle EU/UK/US RCC
SENSOR DATA TRANSMISSION
function, press and hold to turn off RCC function
To search for a sensor:
4. °C/°F - Press to toggle the desired temperature unit
Press and hold
5. RESET – Press to reset all settings to default
The sensor reception icon in the remote sensor area shows
the status:
BACK VIEW
Icon
TIP
The transmission range may vary depending on many
1
2
factors. You may need to experiment with various locations
1. Battery compartment
to get the best results.
2. Battery compartment cover

CLOCK

LCD DISPLAY SCREEN
CLOCK RECEPTION
4 5 6 7
8
This clock is designed to synchronize its clock automatically
with a clock signal. Press
region (EU/UK/US).
Region
1
EU
9
2
UK
3
US
10
11
12
Clock signal reception indicator:
Icons
17
16
15
14
13
1. MAX/MIN temperature indicator
2. Outdoor temperature
(flash)
3.
RCC Clock reception signal indicator
4. Outdoor sensor low battery display
5.
Remote sensor reception indicator
6.
Outdoor temperature auto-loop indicator
NOTE
7. Outdoor sensor channel number
the signal is weak, it could take up to 24 hours to receive a
8. Outdoor temperature trend indicator
valid signal.
9. Outdoor temperature unit display (°C/°F)
You may turn off the clock signal reception and set the clock
manually.
10. Main unit low battery display
To disable signal reception:
11. Indoor temperature trend indicator
12. Indoor temperature unit display (°C/°F)
Press and hold
13. Indoor temperature
NOTE
14. Date/month format display (date: month/month: date)
replacement.
15. Time/Calendar
SET THE CLOCK MANUALLY
16. AM/PM
17. Weekday display
1. Press and hold
2. Press and hold
REMOTE SENSOR (THN132N)
number flashes.
3. Press once or press and hold +/- to adjust the setting.
For EU/UK, the time-zone offset sets the clock up to
+/- 23 hours from the received clock signal time. For US,
the time-zone setting is 0(P), 1(M), 2(C), 3(E).
4. Press
5. Press once or press and hold +/- to adjust the setting for
12/24h hour format, hour, minute, year, calendar format
(month-day/day-month), month, date and language
6. Press
NOTE
(SPA), Italian (ITA), French (FRE) and German (GER).
1. LED status indicator
When the unit is in idle mode, you may choose the display
2. Wall mount hole
mode options.
3. Battery compartment
To select the display mode:
4. RESET hole
Press
5. CHANNEL switch
NOTE
The sensor included in this package can search
channels 1, 2 and 3. To search all 5 channels, you may
purchase additional sensors. Visit www.oregonscientific.com
for more about accessory sensors.

TEMPERATURE

To toggle temperature unit:
Press °C / °F inside the battery compartment.
NOTE
When the indoor temperature is lower than -5 °C
(23.0 °F), the screen displays LL.L. When the temperature
is higher than 50 °C (122.0 °F), the screen displays HH.H.
To toggle sensor display:
MEANING
Press
.
Sensor batteries are low
To auto-loop between sensors:
Main unit batteries are low
Press
repeatedly until the unit displays . The data
on each sensor displays for 3 seconds. Press
Replace the batteries when
displays , or when
turn off the auto-loop, the
NOTE
The sensor displays in ascending order. If not all
5 sensors are present, the main unit skips the absent sensor
and advances to the next present sensor.
To toggle between MAX/MIN and current records for the
selected sensor:
Press MEM repeatedly.
To clear the MAX/MIN records:
Press and hold MEM. All MAX/MIN data of indoor and outdoor
temperature will be cleared and starts to record the current
temperature.
ICE WARNING
If the channel 1 sensor temperature falls between 3°C to -2°C
(37°F to 28°F), LED indicator will flash, and will stop flashing
once the temperature is out of this range. Press – to turn off
the ice warning alert.
NOTE
The ice warning alert turns on again when the
temperature falls into the temperature range.

BACKLIGHT

Press
to turn on the backlight. The backlight will be
on for 5 seconds.
PRECAUTIONS
• Do not subject the unit to excessive force, shock, dust,
temperature or humidity.
• Do not immerse the unit in water. If you spill liquid over it,
1.5m(5ft)
dry it immediately with a soft, lint-free cloth.
• Do not clean the unit with abrasive or corrosive materials.
• Do not tamper with the unit's internal components. This
invalidates the warranty.
• Only use fresh batteries. Do not mix new and old batteries.
• Images shown in this manual may differ from the actual
display.
Use alkaline batteries for longer usage and consumer
• When disposing of this product, ensure it is collected
separately for special treatment.
• Placement of this product on certain types of wood may result
in damage to its finish for which Oregon Scientific will not
be responsible. Consult the furniture manufacturer's care
instructions for information.
.
• The contents of this manual may not be reproduced without
the permission of the manufacturer.
• Do not dispose old batteries as unsorted municipal waste.
Description
Collection of such waste separately for special treatment
Searching for sensor(s).
is necessary.
• Please note that some units are equipped with a battery
safety strip. Remove the strip from the battery compartment
Sensor is found.
before first use.
Cannot find sensors.
NOTE
The technical specifications for this product and the
contents of the user manual are subject to change without
notice.
SPECIFICATIONS
MAIN UNIT
L x W x H
Weight
to turn on and select the desired
Temperature range
Signal
DCF
Resolution
MSF
Accuracy
WWVB
Power
Description
Main unit is searching for
clock signal strength
REMOTE UNIT (THN132N)
Main unit is searching for
clock signal
L x W x H
No clock signal
Weight
Transmission range
It takes 2-10 minutes to receive the clock signal. If
Temperature range
Signal frequency
Power
. The
icon turns off.
ABOUT OREGON SCIENTIFIC
The signal reception is on after each reset or battery
Visit our website www.oregonscientific.com to learn more
about Oregon Scientific products.
For any enquiry, please contact our Customer Services at
to disable signal reception.
info@oregonscientific.com.
. The screen displays ZONE and the
Oregon Scientific Global Distribution Limited reserves the right
to interpret and construe any contents, terms and provisions
in this user manual and to amend it, at its sole discretion, at
any time without prior notice. To the extent that there is any
inconsistency between the English version and any other
language versions, the English version shall prevail.
to confirm.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
to confirm each setting.
not cause harmful interference, and (2) This device must
accept any interference received, including interference that
The language options are English (ENG), Spanish
may cause undesired operation.
WARNING
Changes or modifications not expressly
approved by the party responsible for compliance could void
the user's authority to operate the equipment.
to select between clock and date display.
NOTE
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
again
equipment off and on, the user is encouraged to try to correct
icon turns off.
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
This Class B digital apparatus complies with Canadian ICES-
3(B)/NMB-3(B)
DECLARATION OF CONFORMITY
The following information is not to be used as contact for
support or sales. Please call our customer service number
(listed on our website at www.oregonscientific.com), or on
the warranty card for this product) for all inquiries instead.
We
Name:
Oregon Scientific, Inc.
Address:
10778 SW Manhasset Dr.
Tualatin, Or 97062 USA
Telephone No.:
1-800-853-8883
declare that the product
Product No.:
RMR262
Product Name:
Alizé Thermometer
Manufacturer:
IDT Technology Limited
Address:
Block C, 9/F, Kaiser Estate,
Phase 1, 41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Alizé Thermometer
(model: RMR262) is in compliance with the essential
requirements and other relevant provisions of Directive
1999/5/EC. A copy of the signed and dated Declaration of
Conformity is available on request via our Oregon Scientific
Customer Service.
COUNTRIES RTTE APPROVED COMPLIED
All EU countries, Switzerland
145 x 74 x 19 mm
5.71 x 2.91 x 0.75 in
136 g (4.8 oz) without
batteries
-5°C to 50°C
(23°F to 122°F)
0.1°C (0.2°F)
0°C-40°C: ±1°C (± 2.0°F)
40°C <T<0°C: ±2°C (±
4.0°F)
2 x UM-4 (AAA) 1.5 V
batteries
96 x 50 x 22 mm
(3.78 x 1.97 x 0.87 in)
50 g (1.76 oz) without
batteries
30 m (98 ft) unobstructed
-20 °C to 60 °C
(-4 °F to 140 °F)
433 MHz
1 x UM-3 (AA) 1.5 V
batteries
Termómetro Alizé
Modelo: RMR262
Manual de usuario
ES
DESCRIPCIÓN GENERAL
VISTA FRONTAL
1
1. Indicador de alerta de helada
2. + - Pulse este botón para aumentar el valor del parámetro
o manténgalo pulsado para aumentar el valor con rapidez.
3.
- Pulse este botón para cambiar entre el reloj y la
fecha, o manténgalo pulsado para acceder al modo de
ajustes.
4. MEM – Pulse este botón para mostrar los registros de
temperatura actual, máxima y mínima, o manténgalo
pulsado para borrar los registros de temperaturas
máxima (MAX) y mínima (MIN).
5. – - Pulse este botón para disminuir el valor del
parámetro, o manténgalo pulsado para disminuir el valor
con rapidez.
VISTA SUPERIOR
1
2
3
4
5
1. SENSOR – Pulse este botón para seleccionar un canal
del 1 al 5, o para activar o desactivar la muestra cíclica
de los datos de los sensores en la pantalla. Mantenga
pulsado para buscar el sensor para cada uno de los
canales.
2. LIGHT – Pulse este botón para activar la retroiluminación.
3. RCC – Pulse este botón para activar la función RCC para
EU, UK o US, o manténgalo pulsado para desactivarla.
4. °C/°F - Pulse este botón para seleccionar una unidad de
temperatura.
CH
5. RESET – Pulse este botón para restablecer la unidad a los
and Norway
N
ajustes predeterminados de fábrica.
VISTA TRASERA
1
2
1. Compartimento de las pilas
2. Tapa del compartimento de las pilas
PANTALLA LCD
4 5 6 7
8
1
2
3
17
16
15
14
13
1. Indicador de temperaturas MAX/MIN
2. Temperatura exterior
3.
Indicador de recepción de la señal de la hora
4. Icono de pila baja en el sensor externo
5.
Indicador de recepción del sensor remoto
6.
Indicador de escaneo automático de la temperatura
exterior
7. Número de canal del sensor externo
8. Indicador de la tendencia de la temperatura exterior
9. Unidad de temperatura exterior (°C/°F)
10. Pila baja de la unidad principal
11. Indicador de la tendencia de la temperatura interior
12. Unidad de temperatura interior (°C/°F)
13. Temperatura interior
14. Formato de día del mes/mes (día del mes : mes /
mes : día del mes)
15. Hora/Fecha
16. AM/PM
17. Día de la semana
SENSOR REMOTO (THN132N)
1. Indicador de estado LED
2. Agujero para instalar en la pared
3. Compartimento de las pilas
4. Orificio de reseteo (RESET)
5. Selector de canal (CHANNEL)
2
NOTA
El sensor que se incluye en esta caja puede buscar los
canales 1, 2 y 3. Para buscar los 5 canales, deberá comprar
3
sensores adicionales. Visite www.oregonscientific.com para
más información acerca de los sensores accesorios.
4
PROCEDIMIENTOS INICIALES
5
INSTALACIÓN DE LAS PILAS
1. Retire la tapa del compartimento de las pilas de la unidad
con cuidado.
2. Inserte las pilas haciendo coincidir los polos (+/-).
3. Pulse RESET cada vez que instale pilas nuevas.
UBICACIÓN
SIGNIFICADO
Á r e a d e t e m p e r a t u r a
Pilas bajas del sensor
exterior
Á r e a d e t e m p e r a t u r a
Pilas bajas de la unidad
interior
principal
NOTA
Reemplace las pilas cuando aparezca
o cuando
la pantalla / retroiluminación se atenúe.
SENSOR REMOTO
La unidad principal puede recoger datos de hasta 5 sensores.
Cómo instalar el sensor:
1. Abra el compartimento de las pilas.
2. Seleccione el canal y pulse RESET.
3. Cierre la tpa del compartimento de la pila.
4. Coloque el sensor dentro de un radio de 30 m (98pies) de
la unidad principal usando el pie de apoyo o el soporte
de pared.
CONSEJO
A fin de obtener una lectura precisa, la ubicación
ideal del sensor debe ser en el exterior de la casa a una
altura a 1,5 m (5 pies) y resguardado de la luz directa del
sol o la lluvia.
1.5m(5ft)
NOTA
Utilice pilas alcalinas para un funcionamiento más
prolongado o pilas de litio consumibles cuando las temperaturas
SENSORSMISSION
bajen por debajo de los 0 °C.
TRANSMISIÓN DE LOS DATOS DEL SENSOR
Cómo buscar un sensor:
9
Mantenga pulsado
.
10
El icono de recepción del sensor del área del sensor remoto
11
12
muestra su estado:
Icono
Descripción
Buscando los sensores.
Sensor encontrado.
N o p u e d e e n c o n t r a r
ningún sensor.
CONSEJO
El alcance de la señal de trasmisión puede
variar en función de varios factores. Es posible que necesite
experimentar con diferentes ubicaciones hasta obtener unos
buenos resultados.
RELOJ
RECEPCIÓN DE LA HORA
Este reloj está diseñado para sincronizarse automáticamente
con la señal horaria. Pulse
para activar la recepción de
señal horaria y seleccionar una región (EU/UK/US).
Región
Signal
EU
DCF
UK
MSF
US
WWVB
Indicador de recepción de la señal horaria:
Iconos
Descripción
La unidad está verificando
la intensidad de la señal
horaria.
La unidad está buscando
una señal horaria.
(parpadea)
No hay señal horaria.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RMR262 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Oregon Scientific RMR262

  • Page 1 3. RCC – Press to turn on and toggle EU/UK/US RCC CONSEJO SENSOR DATA TRANSMISSION in damage to its finish for which Oregon Scientific will not A fin de obtener una lectura precisa, la ubicación pulsado para buscar el sensor para cada uno de los...
  • Page 2 11. Indicateur de tendance de la température intérieure necesario desecharlas separadamente para poder tratarlas. HORLOGE la finition du meuble, et Oregon Scientific ne peut en être 12. Unité de l’affichage de la température intérieure (°C/°F) • Tenga en cuenta que algunas unidades disponen de tenu responsable.

Table of Contents