APPENDIX: ELECTRONIC DATA SHEETS
(Programming Information)
Connection Object - Class 5 (05
This device supports Explicit Messaging (Instance 1), I/O Poll
(Instance 2), and I/O Bit Strobe (Instance 3).
DeviceNet Object - Class 3 (03
Attribute
MAC ID (0..63)
Baud Rate
(0=125K, 1=250K, 2=500K)
Bus-Off Interrupt
Bus-Off Counter
Allocation Information
Bus-Off Separation
If Bus-Off Interrupt is true, the device automatically attempts to
recover from a bus-off condition if it is on-line and hasn't been bus-off
since power-up, or if it has sent and received at least Bus-Off Separation
messages since the last bus-off condition.
Presence Sensing Object - Class 14 (0E
Attribute
Output (0..1)
Diagnostic (0=OK, 1=fault)
On Delay (0..65535 mS)
Off Delay (0..65535 mS)
One Shot Delay (0..65535 mS)
Operate Mode
(0=normally open, 1=normally closed)
Switch State (0=nonactuated, 1=actuated)
Head Actuation Count
Maximum Head Actuation Count
Service
Diagnose Nonactuated Switch
Output takes into account the On Delay , Off Delay , One Shot Delay ,
and Operate Mode . Switch state represents the physical location of
the limit switch.
Head Actuation Count increments each time the head is actuated.
When Head Actuation Count reaches 80% or 100% of the Max Head
Actuation Count , a fault is added to the diagnostic object. Maximum
Effective 9/97
), Instances 1, 2 and 3
HEX
), Instance 1
HEX
Attribute ID
Access
1
Get/Set
2
Get/Set
3
Get/Set
4
Get/Set
5
100
Get/Set
), Instance 1
HEX
Attribute ID
Access
1
4
5
Get/Set
6
Get/Set
7
Get/Set
8
Get/Set
100
101
Get/Set
102
Get/Set
Service ID
50
head actuation count is based on Mean Time Between Failure (MTBF)
data and therefore statistically some units could potentially fail earlier
than that, as well as operate well past that number.
The Diagnose Nonactuated Switch service causes the device to
perform a self diagnostic on its sensing circuitry. The test is only
valid if the limit switch is in the nonactuated position. Running this
test is the only way to clear the Diagnostic bit.
Assembly Object Data - Class 4 (04
Attribute
Data
Get
Use Assembly Object Data to read diagnostic and output status. Data
bit 0 is output status, which is obtained from Attribute 1 of the
Presence Sensing Object. Data bit 1 is diagnostic status, which is
obtained from Attribute 4 of the Presence Sensing Object. The
remaining bits (2..7) are 0.
The I/O Poll and I/O Bit Strobe connections consume 0 bytes and
product 1 byte. The one produced byte is Data .
Identity Object - Class 1 (01
Get
Attribute
Get
Vendor (68)
Device Type (4)
Product Code (50)
Revision
Status
Serial Number
Get
Product Name ("E50")
State
Message Router Object - Class 2 (02
Attribute
Object List
), Instance 1
HEX
Attribute ID
3
), Instance 1
HEX
Attribute ID
1
2
3
4
5
6
7
8
), Instance 1
HEX
Attribute ID
1
Page 7
Access
Get
Access
Get
Get
Get
Get
Get
Get
Get
Get
Access
Get