T R O U B L E S H O O T I N G T A B L E
C O N D I T I O N
1.Short circuit at terminals 8 and 10
OVERLOAD LED ON
2.Short circuit at any of the loop detectors in
And
the board
POWER LED OFF
3.Short circuit in the control board
OVERLOAD LED ON
1. Excessive current draw at terminal 10
And
2. Over-voltage at the 120 VAC line input
POWER LED ON
1. One limit switch is faulty
SYSTEM ON LED FLASHING
2. Motor thermal fuse has pop-out
1.Gate has encounter and obstruction during
traveling
REVERSE SENSOR LED ON
2.Reverse sensor is extra sensitive
1.Gate encountered and obstruction during
traveling
ALARM SENSOR LED ON
2.Alarm sensor is extra sensitive
ALARM SENSOR LED ON
1.Gate encountered and obstruction during
traveling
2.Alarm sensor is extra sensitive
1. There is a command hold active
COMMAND PROCESSED ON
TIMER LED BLINKING And
1. There is a command holding the gate open
COMMAND PROCESSED
BLINKING
TIMER LED BLINKING And
1.Gate has reopened because it encountered an
COMMAND PROCESSED
obstruction while closing.
BLINKING
And
REVERSE SENSOR LED ON
1.Gate has encountered two consecutive
AUDIO ALARM ON
obstructions while trying to close or open
1.The loop detector needs to be reset.
ANY "LOOP LED" ON And
2.The wire loop has been disrupted
NO VEHICLE ON THE
3.The loop detector needs to work in a
SENSING AREA
different frequency
4.The loop detector is too sensitive
POSSIBLE CAUSES
S O L U T I O N
1.Remove the short circuit condition at the
terminals
2.Remove the defective loop detector
3.Sent the board to repair
1. Reduce the accessories load from terminal 10
2. Verify your electrical power
1. Test the limit switches and wire connections,
fix the fault
2.Reset the motor
1.Remove the obstruction
2. Turn counter-clock-wise the reverse sensor
pot a bit more and try again
1.Remove the obstruction
2. Turn counter-clock-wise the alarm sensor pot
a bit more and try again
1.Remove the obstruction
2. Turn counter-clock-wise the alarm sensor pot
a bit more and try again
1.This is a normal response of the gate
operator. It does not represent necessarily
that there is a problem.
1.This is a normal response of the gate operator.
It does not represent necessarily that there is a
problem. Check inputs for command.
1.Any re-new command will resume normal
operation. Check for obstructions.
2. You can stop the alarm by using the stop
button.
1.Any re-new command will resume normal
operation but not a radio command. Check
for obstructions.
1.Reset the loop detector (If you use Elite
Plug-in Loop detectors, change the setting
for sensitivity and come back to your original
setting).
2. Verify and correct connections
3.Set a different working frequency
4.Decrease the sensitivity of the loop detector