Issue 01/05
5.7.1.4
Execute the mapping for TPDO 5
Set the number of mapped objects to 0
Write 0 into object 0x1A05 sub 0
T0 00:01:56,7626: 0x603
R0 00:01:56,7748: 0x583
The status word is the first mapped object:
Write 0x60410010 into object 0x1A05 sub 1
T0 00:01:56,8695: 0x603
R0 00:01:56,8819: 0x583
Modes of operation display is the second mapped object:
Write 0x60610008 into object 0x1605 sub 2
T0 00:01:56,9977: 0x603
R0 00:01:57,0108: 0x583
Set the number of mapped objects to 2
Write 2 into object 0x1A05 sub 0
T0 00:01:57,1004: 0x603
R0 00:01:58,7806: 0x583
Set the nodes into the operational mode:
T0 00:01:58,8546: 0x000
Receive the three PDOs:
R0 00:01:58,8655: 0x183
R0 00:01:58,8741: 0x283
R0 00:01:58,8816: 0x383
Run-through the state machine of the drive:
Send 6 using PDO 1
T0 00:01:58,9832: 0x203
Send 7 using PDO 1
T0 00:01:59,0533: 0x203
Receive the three PDOs:
R0 00:01:59,0953: 0x183
R0 00:01:59,1038: 0x283
R0 00:01:59,1113: 0x383
Send F using PDO 1
T0 00:01:59,1569: 0x203
CANopen Option Module
Operating Instructions
6SE6400-5BC00-0BP0
Information for the CANopen master
8-Data: 2f 05 1a 00 00 00 00 00
8-Data: 60 05 1a 00 00 00 00 00
8-Data: 23 05 1a 01 10 00 41 60
8-Data: 60 05 1a 01 00 00 00 00
8-Data: 23 05 1a 02 08 00 61 60
8-Data: 60 05 1a 02 00 00 00 00
8-Data: 2f 05 1a 00 02 00 00 00
8-Data: 60 05 1a 00 00 00 00 00
2-Data: 01 03
2-Data: 31 fe
4-Data: 31 fe 00 00
3-Data: 31 fe 02
2-Data: 06 00
2-Data: 07 00
2-Data: 33 fe
4-Data: 33 fe 00 00
3-Data: 33 fe 02
2-Data: 0f 00
93