Siemens MICROMASTER 420 Operating Instructions Manual page 27

Canopen option module
Hide thumbs Also See for MICROMASTER 420:
Table of Contents

Advertisement

Issue 01/05
O-Ind
S-
Object name
Ind
6040H
Control word
6041H
Status word
6042H
Vl_target_vel
ocity
6043H
Vl_velocity
_demand
6044H
Vl_control_eff
ort
6046H
Vl_velocity_m
in_max_amo
unt
.0
Number of
entries
.1
Vl_velocity_m
in_amount
CANopen Option Module
Operating Instructions
6SE6400-5BC00-0BP0
Description
Transf.
using
CANopen control
SDO/
word
PDO
CANopen status word SDO/
PDO
Reference (target)
SDO/
velocity of the velocity
PDO
mode
Velocity, controlled
SDO/
quantity
PDO
Velocity actual value
SDO/
PDO
Minimum and
maximum absolute
value for the velocity
limiting
No. of sub-indices
SDO
Absolute value of the
SDO
minimum velocity
limiting
Data transfer using CANopen
D-type /
Default value / comment
access
U16 /
0 /
wo
This is converted and mapped to the
MICROMASTER control word 1 (r0054) when
being transferred to the MICROMASTER.
Parameter 22BCH* must be set to 6 so that
the CANopen control word can control the
MICROMASTER.
U16 /
0 /
ro
MICROMASTER status word 1 (r0052) is
converted when being transferred from
MICROMASTER and is mapped onto the
CANopen status word. Parameter 22BCH*
must be set to 6 so that the CANopen status
word can send MICROMASTER status onto
the CAN bus.
I16 /
0 RPM /
rw
Parameter 23E8H* must first be set to 6 (via
CAN), or a BICO connection must be
established from P2050.1 to the speed
setpoint. Up until now, this BICO connection
can only be established with the BOP or using
the start-up tool.
I16 /
0 RPM /
ro
Parameter 23E8H* must first be set to 6 (via
CAN) or a BICO connection must be
established from r0021 to P2051.1.
Up until now, this BICO connection can only
be established with the BOP or using the start-
up tool.
I16 /
0 RPM /
ro
A BICO connection must be established from
r0063 to P2051.
Up until now, this BICO connection can only
be established with the BOP or using the start-
up tool.
U8 / ro 2 /
-
U32 /
0 /
rw
(P1080 . 60 / r0313) RPM /
Acts on P1080 (2438H*). When this object
changes, this effects the gradient (rate-of-rise)
of the up ramp.
27