Raymarine ST60+ Tridata Owner's Handbook Manual page 50

Hide thumbs Also See for ST60+ Tridata:
Table of Contents

Advertisement

38
5. At the end of the outward leg, press the speed button again so that:
• The text rEtrn is flashing at the bottom of the screen.
• The displayed distance freezes. Note that this value may not be the same
6. Turn the vessel round, start the return leg and as you do so, press the speed
button so the rEtrn legend stops flashing and the displayed value incre-
ments.
7. At the end of the return leg, press the speed button to end the calibration
run. At this point:
• The text Strt 2 alternating with the new calibration factor is displayed
• The displayed distance freezes. This value should be very close to the
speed
From sheet 1
Complete the
return leg of
the second cal run
At the end of
the return leg
press
speed
Speed calibration, sheet 2
8. Carry out one of the following actions:
• If you are satisfied with the results of the first calibration run, press the
as the measured distance due to errors introduced by tidal flow.
at the bottom of the screen.
actual (measured) distance of the calibration run.
Speed
calibration is
now complete
and speed buttons together, to store the new calibration factor,
depth
exit speed calibration and return to the Instrument status screen.
ST60+ Tridata Instrument Owner's Handbook
Complete the
outward leg of
the second cal run
At the end of the
outward leg, press
At the start of the
return leg press
speed
Press
+
depth
speed
to save the
cal factor
speed
Exit to Instrument
status display
(Intermediate
calibration)