26
This requirement depends on the total length of the cable run and the total
number of instruments in the system, as follows:
Cable run
Up to 10 m
Up to 20 m
(typically provided
SeaTalk power connections
Stand alone instruments
Stand-alone instruments are not connected to SeaTalk and therefore need to be
connected to an alternative 12 V power source. Power cables are available in 2 m
and 9 m lengths.
To fit a power cable:
1. Ensure the intended power source is switched off. If you are using a 12 V bat-
tery, ensure the power cable is not connected to the battery.
2. Run the power cable from the instrument to a suitable 12 V dc power source.
3. If the cable has not already been trimmed at the power supply end:
• Cut the cable to length and trim back an appropriate amount of the outer
• Cut back and insulate the yellow wire.
4. Connect the screen to the power supply 0 V terminal.
5. Connect the red wire, via a 3 A fuse or protective circuit breaker, to the power
supply +12 V terminal.
No. of instruments
13 maximum
26 maximum
7 maximum
13 maximum
Red
5 A fused,
12 V dc supply
by autopilot)
Screen
Red
Screen
sheath.
ST60+ Tridata Instrument Owner's Handbook