Watec WAT- 320DW Operation Manual

Monochrome ccd camera

Advertisement

Quick Links

Monochrome CCD Camera
WAT
WAT- - - - 320DW
WAT
WAT
320DW
320DW
320DW
Operation Manual
This Operation Manual covers safety, camera functions, installation and
the correct operating procedure for the WAT-320D/W. First, we ask you
to read this Operation Manual thoroughly, then install and operate the
WAT-320D/W as advised. In addition, for future reference, we also
advise safe keeping of this manual.
Please contact the distributor or dealer from which the WAT-320D/W
was purchased, if you do not understand the installation, operation or
safety instructions laid out in this manual. Not understanding the
contents of the Operation Manual sufficiently may cause damage to the
camera.
Guide to the safety symbols
The meanings of the symbols used in this operation manual are:
When you do not adhere to or take notice of the "Danger"
Danger
sign, it may lead to a serious accident such as death or
injury caused by fire or electric shock.
When you do not adhere to or take notice of the "Warning"
War ni ng
sign, it may cause severe damage such as a physical injury.
When you do not adhere to or take notice of the "Caution"
Cauti on
sign, it may incur injury and cause damage to peripheral
objects in the immediate surroundings.
Cautions for safety
The WAT-320D/W is designed to be used safely; however, electrical
goods may lead to a physical accident caused by fire and electric shock
if not used correctly. Therefore, please keep and read the "Cautions for
safety" for protection against accidents.
Do not disassemble and/or modify the WAT-320D/W.
Danger
Do not operate the WAT-320D/W with wet hands.
Use a stabilized power adaptor designed for DC+12V± ± ± ±
Warning
10%, with a current capacity of more than 250mA for
the WAT-320D/W.
The recommended voltage is DC+12V±10%
Protect the WAT-320D/W from condensation.
Keep the
dry at all times during storage and
WAT-320D/W
operation.
Should the camera not work properly, switch off the power
immediately. Then check the camera according to the
"Problems and Trouble Shooting" section.
Avoid the striking of hard objects or dropping the
Caution
WAT-320D/W.
The
WAT-320D/W
uses high quality electrical parts and
precision components.
iDo not connect any power supply directly to the video
out terminal of the unit.
Do not connect the
WAT-320D/W
with any monitor using a
video/power single transmission terminal. The
WAT-320D/W
is not designed for use with this type of
equipment. We also advise you to read the operation
manual of the monitor you plan to use before any
connections are made.
Do not install the WAT-320D/W in a position subject to
direct sunlight.
Sunlight shinning directly onto the
WAT-320D/W
cause damage to the CCD.
Select a stable place for installation of the
WAT-320D/W.
Use a support of durable strength around an installation
position on a ceiling or wall when a camera stand or tripod
is used.
Do not move the WAT-320D/W with the cables
connected.
Before moving the
WAT-320D/W
, always remove the video
cable and power cable from the rear of the camera first.
Avoid using the WAT-320D/W near any strong
electromagnetic field.
After installing into main equipment, if the
WAT-320D/W
exposed to electromagnetic waves causing the monitored
image to become distorted, we recommend the camera be
shielded by appropriate protective casing.
EMC Conformity
The WAT-320D/W is in conformity with EMC test standards carried out
by authorized organizations in Japan.
E I A
FCC Part15 class B
Do not modify the WAT-320D/W. A Modified camera may
Danger
not conform to EMC test standards.
Problems and Trouble Shooting
If any of the following problems occur when using the
WAT-320D/W,
An optimal picture cannot be obtained, after checking that all the
cables and connections are correctly in place.
Smoke or any unusual odor emerges from the WAT-320D/W.
An object becomes embedded or a quantity of liquid seeps into the
camera housing.
More than the recommended voltage or/and amperage has been
applied to the WAT-320D/W by mistake.
Anything unusual occurring to any equipment connected to the
WAT-320D/W.
Disconnect the camera immediately according to the following
procedures:
①Switch off the main power supply to the camera.
②Remove the power and video cables connected to the WAT-320D/W.
③Contact the distributor or dealer from which the WAT-320D/W was
purchased.
Contents
Check to make sure all parts are present before use.
Power Supply
Use a stabilized power adaptor designed for DC+12V±10%, with a
current capacity of more than 250mA.
Description of parts
lens can
is
①FRONT GLASS (Tempered glass)
・ ・ ・ ・ Dirt, water or oil deposits on the front glass will cause an unclear
picture on the monitor and scratches might become permanent
damage. Do not dismount the front glass.
②HOUSING MAIN BODY
・ ・ ・ ・ This case is uses aluminum and is given alumite treatment.
③TRIPOD MOUNTING SCREW HOLES
・ ・ ・ ・ Mounting holes for stands. The size of these threads are 1/4", 20
threads, 4.5±0.2mm, which is the same as any standard camera
tripod (U1/4").
④BRACKET
・ ・ ・ ・ The bracket for fixing to the camera.
⑤BRACKET MOUNTING SCREWS
・ ・ ・ ・ The screws for mounting the bracket to the camera.
⑥POWER IN
・The terminal designed for connection with the DC-plug of the power
adaptor.
⑦VIDEO OUT (BNC)
・ ・ ・ ・ The terminal for composite video signal output.
Set-up and Operation
1) Ensure that the power to the WAT-320D/W and the peripheral
equipment is turned off before making any connections.
2) Connect ⑦VIDEO OUT on the WAT-320D/W with the monitor, using
a coaxial cable with 75Ω impedance, such as an RG-58/U or an
RG-6/U. Select a monitor with the same television system as the
WAT-320D/W: EIA or CCIR. A monitor with more than 600TV lines is
recommended.
3) Insert the power plug of the power adaptor into ⑥POWER IN.
Confirm that the power adaptor is not connected to the power supply
before insertion of the power plug into ⑥POWER IN.
4) Turn on the power to the WAT-320D/W, monitor and all other allied
equipment. When a picture cannot be obtained on the monitor, check
and follow the procedure mentioned in the【Problems and Trouble
Shooting】section.
6) When a change of installation position is required, set ④BRACKET
to your required position after removing ⑤BRACKET MOUNTING
SCREWS from the WAT-320D/W, then retighten ⑤ BRACKET
MOUNTING SCREWS firmly. Angular settings for ceiling and wall
are also available.
<Back side of the WAT- 320D/W>

Specifications

Model
Pick-up Element
1/2 inch interline transfer CCD image sensor
Number of Total Pixels
Number of
Effective Pixels
Unit Cell Size
Sync. System
Scanning System
Video Output
Composite video, 1.0 V(p-p), 75Ω(Unbalanced)
Resolution (H)
Minimum Illumination
Wavelength
LED
IR Distance
IR LED
S/N
A/E mode
AGC
Gamma
Characteristics
Power Supply
Power Consumption
2.04W (170mA) / Max: 3.84W (320mA)
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Built-in Lens
Cable Length
Size
Weight
Design and specifications are subject to change without notice.
Watec is not responsible for any inconvenience or the attendant damages
to the video and monitoring recording equipment caused by misuse, mis-
operation or improper wiring of our equipment.
If for any reason the WAT-320D/W does not work properly, or if you have
any questions regarding installation or operation, please contact the
distributor or dealer from which it was purchased.
Contact information
Add.: 254-2 Nihonkoku, Daihoji, Tsuruoka- Shi,
Yamagata-Ken, 997-0017 Japan
TEL:
+81-235-23-4400 FAX: +81-235-23-4409
Email: info-o@watec.co.jp
URL:
http://www.watec.net
<④BRACKET >
WAT-320D/W (EIA)
811(H)×508(V)
768(H)×494(V)
8.4μm(H)×9.8μm(V)
Internal
2:1 interlaced
More than 570TVL (Center)
0 lx. (at IR LED)
940nm
30m
12 units
More than 50dB (AGC=5dB, γ=1.0)
1/60 – 1/100000 sec.
5 – 50dB
γ≒0.35
DC+12V±10%
-10 - +50℃ (Without condensation)
Less than 95% RH
-30 - +70℃ (Without condensation)
Less than 95% RH
Mono-focal lens (f=8.0 F1.6)
10m
φ72 × 98 (mm)
Approx. 1.1g (Including cable)
Watec Co., Ltd.