Section 4 • Repair Procedures
72 Slide the number 1 outer arm (index #22) to the
non-steer end and remove it from the machine.
Bodily injury hazard. The number
1 outer arm may become
unbalanced and fall if not properly
supported when removed from the
machine.
73 Attach the strap from an overhead crane to the
number 1 inner arm (index #10). Do not lift it.
74 Remove the upper fasteners securing the
number 1 inner arm pivot bracket to the end of
the chassis. Loosen the lower fasteners.
75 Remove the number 1 inner arm (index #10)
from the machine.
Bodily injury hazard. The number
1 inner arm may become
unbalanced and fall if not properly
supported when removed from the
machine.
Component damage hazard. Be
sure not to damage the limit switch
or level sensor box components
when the number 1 inner arm is
removed from the machine.
4 - 48
How to Replace the Scissor Arm
Wear Pads
1 Remove the platform. See 2-1, How to Remove
the Platform.
2 Support and secure the entry ladder to an
appropriate lifting device.
3 Remove the fasteners from the entry ladder and
remove the entry ladder from the machine.
4 Secure the ends of the scissor arms together at
the steer end of the machine with a strap or
other suitable device.
5 Secure the ends of the scissor arms together at
the non-steer end of the machine with a strap or
other suitable device.
6 Remove the retaining fasteners securing the
chassis mount bracket to the chassis at the
steer end of the machine.
7 Attach a lifting strap from an overhead crane to
the scissor arm assembly.
8 Raise the scissor arm assembly at the steer
end with the overhead crane until the chassis
mount bracket will clear the level sensor.
GS-30 • GS-32 • GS-46
March 2007
Crushing hazard. The entry ladder
may become unbalanced and fall
if not properly supported and
secured to the lifting device.
Part No. 97385