4.2.
Oven Model Set Up and Configuration
The control must be able to drive multifunction cavities, with one or two convection fans, and thermal cavities. Different oven mod-
els are possible as described in the following table.
4.2.1.
Set Up
IMPORTANT: The MANUAL TEST procedure can be activated only within 5 minutes after power on.
The MANUAL TEST must be completed until the writing TEST END appears otherwise the oven model configuration
will be lost.
The manual test procedure must be completed when the main power board is replaced and confirmed as per the instructions in this
section. If the control has never been configured before, the display shows F11Err at power up. Once a configuration has been
accepted, the failure disappears.
At every POWER-UP, the control runs a latch auto-test cycle. The lock icon flashes while the latch is moving.
• Hold [A]
and [F]
turn on for about 5 seconds.
• Press [+]
to enter test mode then press [+] to get into the next step. Press [-]
• Check the display board SOFTWARE VERSION (d05).
• Push [+] and Check the main power board SOFTWARE VERSION (P18).
• Whether the oven model has been correctly detected.
Otherwise:
• Hold [A]
key, the oven model starts flashing on the display.
• Hold [C]
/ [D]
keys in order to select the correct model n03.
• Hold [A]
again to confirm.
(OTHERWISE CHECK WHETHER THE CONFIGURATION HAVE BEEN SET PROPERLY, AS DESCRIBED AT THE BEGINNING)
SIZE
n 03
30
SINGLE
button at the same time, for about 3 seconds, and check that all the display elements and the buzzer
OVEN
MAIN CAVITY
CONVECT 2 FAN
5
80C
to come back to the previous one.