7.22. Meat probe board replacement
1. Disconnect the power supply cord and remove the Oven
from the cabinet.
2. Remove the upper cover.
3. Remove the screws connecting the meat probe power
board.
4. Replace the new board using the spacers.
5. Connect the cable following the electric diagram.
6. IT IS VERY IMPORTANT TO CONNECT THE CABLES
IN THE RIGHT POSITION.
7. The connections must not be loose.
8. Reconnect the power supply cord before installing the
Oven and check all functions.
9. Disconnect the power supply cord and reinstall the Oven
into the cabinet.
10. Reconnect the power supply cord after installing.
11. Run the Oven and check all functions.
7.23. Meat probe connection
1. Disconnect the power supply cord and remove the Oven
from the cabinet.
2. Remove the MEAT PROBE cover by its three screws
(fig1).
3. Check the connection cable.
4. IT IS VERY IMPORTANT THAT ALL THE WIRES OR
TERMINALS MUST NOT BE IN CONTACT WITH THE
ALUMINUM INSULATION FOIL. (Fig2)
5. THE PROBE JACK INSERTED MUST BE IN CONTACT
WITH BOTH METAL BLADES OF FEM-ALE PLUG.
(Fig3)
6. The connections must not be loose.
7. Reconnect the power supply cord before installing the
Oven and check all functions.
8. Disconnect the power supply cord and reinstall the Oven
into the cabinet.
9. Reconnect the power supply cord after installing.
10. Run the Oven and check all functions.