Summary of Contents for Burkert AirLINE 8644

  • Page 1: Operating Instructions

    Type 8644 AirLINE With decentralized peripheral system ET200S (Siemens) Operating Instructions Bedienungsanleitung Manuel d‘utilisation...
  • Page 2 We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. © Bürkert Werke GmbH & Co. KG, 2002 - 2018 Operating Instructions 1805/10_EU-EN_00804729 / Original DE...
  • Page 3: Table Of Contents

    Type 8644  Type 8644 AirLINE - Siemens able of onTenTs Operating instructiOns ................................6 1.1. symbols ......................................6 authOrized use .....................................7 2.1. restrictions ....................................7 2.1.1. Explosion protection approval ........................ 7 Basic safety instructiOns ..............................8 general infOrmatiOn ................................9 4.1. contact addresses ................................9 4.2. Warranty ......................................9 4.3. licenses ......................................9 4.4. information on the internet .
  • Page 4 Type 8644  6.4.1. Dimensioning of the connection modules ..................19 6.4.2. Performance features from the point of view of the entire system..........20 6.5. electrical data ..................................21 6.5.1. Electronic base module ME02, ME03 / 2-fold monostable ............21 6.5.2. Electronic base module ME02, ME03 / 4-fold monostable ............22 6.5.3.
  • Page 5 Type 8644  7.5.1. General Description ..........................50 installatiOn ....................................53 8.1. safety instructions ................................53 8.2. removing the valve block from the top-hat rail ....................54 8.3. installing the airline system (e.g. in the control cabinet) ................56 8.4. changing the function module ............................56 8.5. fluid installation ..................................57 8.5.1. Pneumatic connections - feed ......................58 8.5.2. Removing the plug-in connections......................58 8.5.3. Pneumatic connections - valve discs ....................59 8.6. electrical installation .
  • Page 6: Operating Instructions

    Type 8644 OperatingInstructions OperaTing insTrucTiOns The operating instructions describe the entire life cycle of the device. Keep these instructions in a location which is easily accessible to every user, and make these instructions available to every new owner of the device. WArNINg! the operating instructions contain important safety information! Failure to observe these instructions may result in hazardous situations.
  • Page 7: Authorized Use

    Type 8644 Authorizeduse auThOrized use non-authorized use of the airline may be dangerous to people, nearby equipment and the environment. • The device is designed for use in an environment where there is a risk of explosion. Pneumatically operated devices may be used for control. • Do not use the device outdoors unprotected. • Use according to the authorized data, operating conditions and conditions of use specified in the contract documents and operating instructions.
  • Page 8: Basic Safety Instructions

    Type 8644 BasicSafetyInstructions Basic safeTy insTrucTiOns These safety instructions do not make allowance for any: • Contingencies and events which may arise during the installation, operation and maintenance of the devices. • Local safety regulations – the operator is responsible for observing these regulations, also with reference to the installation personnel.
  • Page 9: General Information

    International Contact addresses can be found on the final pages of the printed operating instructions. And also on the Internet at: www.burkert.com 4.2. Warranty The warranty is only valid if the device is used as intended in accordance with the specified application conditions.
  • Page 10: System Description

    Type 8644 SystemDescription sysTem descripTiOn 5.1. application area The AirLINE system is designed for decentralized use in industrial environments. Electronics and fluidics can be combined particularly easily and efficiently thanks to the modular design. DANgEr! danger of explosion! If systems in the explosion-protected area are installed in a control cabinet, the following requirements must be met: •...
  • Page 11: Structure Of The System

    Type 8644 SystemDescription The Type 8644 Bürkert AirLINE is an electrical and pneumatic automation system which was developed for use in the control cabinet or switch box. In a continuous system all electronic and pneumatic components are standardized, enabling pneumatic, electric and electronic modules with various functions to be combined very easily with each other by the observation of simple rules.
  • Page 12: Characteristic Features And Advantages

    Type 8644 SystemDescription 5.4. characteristic features and advantages 5.4.1. characteristic features of airline • Easy to handle • Function block-oriented structure of the switch box or control cabinet • Automatic setup of potential groups, electric, data, and safety circuits • Open, flexible and modular structure • Combination of the valve discs and terminals in different granularity (2-fold, 4-fold,...) for space-optimized station structure 5.4.2.
  • Page 13: Diagram Of The Valve Block

    Type 8644 SystemDescription 5.5. diagram of the valve block Panel (optional pressure gauge to indicate operating pressure on the station) 4-fold valve disc 2-fold valve disc Connection Intermediate feed module on left 2-fold valve disc Connection module on right Working connections Supply and vent connections ...
  • Page 14: Exploded Drawing

    Type 8644 SystemDescription 5.6. exploded drawing 5.6.1. exploded drawing - add-on dimension 11 mm  Siemens field bus node Siemens power module ME02 4-fold valve disc 2-fold valve disc ME02 2-fold valve disc ME02 ME02 MP11 Siemens termination module Bulkhead Type 6524 (2x3/2-way) Type 6524 Cover plate Type 6525 Type 0460 Figure 4:...
  • Page 15: Exploded Drawing - Add-On Dimension 16.5 Mm

    Type 8644 SystemDescription 5.6.2. exploded drawing - add-on dimension 16.5 mm  Siemens field bus node Siemens power module ME03 4-fold valve disc 2-fold valve disc ME03 3-fold valve disc 2-fold valve disc ME03 ME03 Siemens termination module MP12 Accessories Type 6526 Cover Type 6527 Cover plate Type 6524 Type 0461 Type 6525...
  • Page 16: Technical Data

    Type 8644 TechnicalData Technical daTa 6.1. Operating conditions WArNINg! risk of injury! Malfunction if used outside! • Do not use Type 8644 AirLINE system outdoors and avoid heat sources which may cause the permitted tem- perature range to be exceeded. permitted temperatures Storage temperature: -20 ... +60 °C Permitted air humidity: 75% on average, 85% occasionally Permitted air pressure...
  • Page 17: Technical Data Of The Valve Block

    Type 8644 TechnicalData max. power consumption I_Log = I_Log_FBKN + Σ I _Module Logic current I_Log Power consumption in the logic area I_Log_FBKN Proportionate current in the field bus node ET200S max. 150 mA I_Module Proportionate current in the logic area of the electronic base modules max 10 mA each field bus node see Siemens handbook...
  • Page 18 Type 8644 TechnicalData ambient temperature 0 ... +55 °C 0 ... +55 °C 0 ... +55 °C Operating voltage 24 V / DC, -15 % / +20 % tolerance**, Residual ripple for field bus interface 5 % * Power reduction (in the module) ** For the Ex-version maximum +10 % *** The following restrictions apply to the power supply tolerances of the entire system (see Technical Data of the entire system): Valve type: 0460 ±...
  • Page 19: Pneumatic Data Of The Connection Modules

    Type 8644 TechnicalData 6.4. pneumatic data of the connection modules Permitted temperature (storage / transport) -20 ... +60° C Permitted air humidity (operation) 75 % on average, 85 % occasionally CAuTIoN! In the range of 0 – +55 °C take suitable measures against increased air humidity (> 85 %). Slight condensation may occasionally occur on the external housing for a brief period, e.g.
  • Page 20: Performance Features From The Point Of View Of The Entire System

    Type 8644 TechnicalData 6.4.2. performance features from the point of view of the entire system connection module on left (me02, me03) The connection module on left is electrically passive → logical no process image, therefore no address is required → mechanical ME02 - 47 mm installation dimension ME03 - 56 mm installation dimension → electrical no power consumption →...
  • Page 21: Electrical Data

    Type 8644 TechnicalData 6.5. electrical data 6.5.1. electronic base module me02, me03 / 2-fold monostable technical data me02 / 2-fold me03 / 2-fold monostable monostable Dimensions WxHxD 22 x 70.5 x 52 mm 33 x 93 x 60 mm Weight 35 g 47 g Storage temperature -20 ... +60° C -20 ... +60° C Nominal load voltage DC 24 V DC 24 V...
  • Page 22: Electronic Base Module Me02, Me03 / 4-Fold Monostable

    Type 8644 TechnicalData 6.5.2. electronic base module me02, me03 / 4-fold monostable technical data me02 / 4-fold me03 / 4-fold monostable monostable Dimensions WxHxD 44 x 70.5 x 52 mm 66 x 93 x 60 mm Weight 56 g 75 g Storage temperature -20 ... +60° C -20 ... +60° C Nominal load voltage DC 24 V DC 24 V Number of valve outputs...
  • Page 23: Electronic Base Module Me02, Me03 / 2-Fold Bistable

    Type 8644 TechnicalData 6.5.3. electronic base module me02, me03 / 2-fold bistable technical data me02 / 2-fold me03 / 2-fold bistable bistable Dimensions WxHxD 22 x 70.5 x 52 mm 33 x 93 x 60 mm Weight 35 g 44 g Storage temperature -20 ... +60° C -20 ... +60° C Nominal load voltage DC 24 V DC 24 V Number of valve outputs...
  • Page 24: Electronic Base Module Me02 / 2-Fold 2 X Monostable

    Type 8644 TechnicalData 6.5.4. electronic base module me02 / 2-fold 2 x monostable technical data me02 / 2-fold 2 x monostable Dimensions WxHxD 22 x 70.5 x 52 mm Weight 38 g Storage temperature -20 ... +60° C Nominal load voltage DC 24 V Number of valve outputs 2 x 2 Power consumption per valve location 2 x 43 mA Power consumption per valve location after 110 ms 2 x 18 mA...
  • Page 25: Electronic Base Module Me03 / 3-Fold 10 Mm Monostable

    Type 8644 TechnicalData 6.5.5. electronic base module me03 / 3-fold 10 mm monostable technical data me03 / 3-fold 10 mm monostable Dimensions WxHxD 33 x 93 x 60 mm Weight 45 g Storage temperature -20 ... +60° C Nominal load voltage DC 24 V Number of valve outputs Power consumption per valve location during switching 43 mA Power consumption per valve location after 28 mA...
  • Page 26: Structure And Function Of The Modules

    Type 8644 Structureandfunctionofthemodules sTrucTure and funcTiOn Of The mOdules 7.1. Valve block The valve block is composed of the following assemblies: • Connection modules / feeds (grouped connections for supply, exhaust air and control assist air), • Valve discs (working connections, various valves). Valve discs Intermediate 4-fold feed...
  • Page 27: Valve Discs Mk03

    Type 8644 Structureandfunctionofthemodules Electrical Electrical Electrical 1:1 shunting connection module connection module Pneumatic Pneumatic Pneumatic feed module feed module feed module connection module intermediate connection module on left feed on right  Figure 7: Schematic representation of feed 7.1.2. Valve discs mK03 DANgEr! danger – high pressure! • Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines. structure Valve discs are modular in design and consist of: •...
  • Page 28 Type 8644 Structureandfunctionofthemodules On the electronic base module the digital outputs are switched where the valves are located. Depending on the operating principle of the valve, these outputs switch the internal P channel to the working connections (outputs) of the pneumatic base modules. NoTE! •...
  • Page 29: Connection Modules

    Type 8644 Structureandfunctionofthemodules 7.2. connection modules 7.2.1. structure of the connection module  Panel Assembly variant with pressure gauge Pneumatic feed Electrical connection module Type MP11/MP12 (left, middle, right) Type ME02/ME03 (left, right) Interface to electrical part of the automation system (field Shunting bus nodes; electrical modules/ (socket on left, plug on right) terminals) Electrical interface for data shunting...
  • Page 30 Type 8644 Structureandfunctionofthemodules Variants The feeds were designed in different variants to meet diverse requirements. To facilitate start-up and diagnosis, feeds are available with a pressure gauge. You receive the fluid connections with straight or conical screw connections as well as with quick-connect systems. The fluid connections can be used differently for special functions.
  • Page 31: Connection Modules, Pneumatic - On Left Type Me02

    Type 8644 Structureandfunctionofthemodules 7.2.2. connection modules, pneumatic - on left Type me02 Variant drawing Pressure gauge Panel Electrical interface Bürkert/Siemens in the valve block (AirLINE) Pneumatic connections  Figure 10: Side feed on left Variants supply connection (p) 1 connection X exhaust air connection (r/s) 3/5 G 1/4 G 1/4 NPT 1/4 NPT 1/4 • Version available with and without pressure gauge Connection X Operation configuration of X...
  • Page 32: Connection Modules, Pneumatic - In Middle Type Me02

    Type 8644 Structureandfunctionofthemodules 7.2.3. connection modules, pneumatic - in middle Type me02 Variant drawing Pressure gauge Panel Pneumatic connections  Figure 11: Intermediate feed Variants supply connection (p) 1 connection X exhaust air connection (r/s) 3/5 G 1/4 G 1/4 NPT 1/4 NPT 1/4 • Version available with and without pressure gauge Connection X Operation configuration of X Standard Exhaust air pilot valve...
  • Page 33: Connection Modules, Pneumatic - On Right Type Me02

    Type 8644 Structureandfunctionofthemodules 7.2.4. connection modules, pneumatic - on right Type me02 Variant drawing  Pressure gauge Panel Electrical interface Bürkert/Siemens in the valve block (AirLINE) Pneumatic connections Figure 12: Side feed on right Variants supply connection (p) 1 connection X exhaust air connection (r/s) 3/5 G 1/4 G 1/4 NPT 1/4 NPT 1/4 • Version available with and without pressure gauge Connection X Operation configuration of X...
  • Page 34: Connection Modules, Pneumatic - On Left Type Me03

    Type 8644 Structureandfunctionofthemodules 7.2.5. connection modules, pneumatic - on left Type me03 Variant drawing  Panel Pressure gauge Electrical interface Bürkert/Siemens in the valve block (AirLINE) Pneumatic connections Figure 13: Side feed on left Variants supply connection (p) 1 connection X exhaust air connection (r/s) 3/5 G 3/8 G 1/8 G 3/8 NPT 3/8 NPT 1/8 NPT 3/8 •...
  • Page 35: Connection Modules, Pneumatic - In Middle Type Me03

    Type 8644 Structureandfunctionofthemodules 7.2.6. connection modules, pneumatic - in middle Type me03 Variant drawing  Pressure gauge Panel Pneumatic connections Figure 14: Intermediate feed Variants supply connection (p) 1 connection X exhaust air connection (r/s) 3/5 G 3/8 G 1/8 G 3/8 NPT 3/8 NPT 1/8 NPT 3/8 • Version available with and without pressure gauge Connection X Operation configuration of X...
  • Page 36: Connection Modules, Pneumatic - On Right Type Me03

    Type 8644 Structureandfunctionofthemodules 7.2.7. connection modules, pneumatic - on right Type me03 Variant drawing Pressure gauge Panel Electrical interface Bürkert/Siemens in the valve block (AirLINE) Pneumatic connections  Figure 15: Side feed on right Variants supply connection (p) 1 connection X exhaust air connection (r/s) 3/5 G 3/8 G 1/8 G 3/8 NPT 3/8 NPT 1/8 NPT 3/8 •...
  • Page 37: Electronic Base Module

    Type 8644 Structureandfunctionofthemodules 7.3. electronic base module 7.3.1. general description The electronic base module is connected to the adjacent modules via its electrical interface. In this way it receives both the power supply and the control signals for the valves on the slots. The electronic base modules and therefore the valve discs can be controlled as digital output modules / terminals.
  • Page 38 Type 8644 Structureandfunctionofthemodules Combination options (electronic base module / valve) Base module type add-on Valve locations Valve type Operating principle dimension ME02 2-fold 11 mm 6524 3/2-way monostable 6525 5/2-way 2-fold 11 mm 0460 5/3-way bistable 5/2-way impulse 2-fold 11 mm 6524 2 x 3/2-way 2 x monostable 4-fold 11 mm...
  • Page 39: Electronic Base Module Me02 / 2-Fold Monostable

    Type 8644 Structureandfunctionofthemodules 7.3.2. electronic base module me02 / 2-fold monostable Structure An electrical base module consists of a distributor module (backplane bus) and a function module. Both modules are contacted via a 14-pole board-to-board plug. The bus signals on the distributor module are protected from interference by a shield support.
  • Page 40: Electronic Base Module Me02 / 4-Fold Monostable

    Type 8644 Structureandfunctionofthemodules 7.3.3. electronic base module me02 / 4-fold monostable Structure An electrical base module consists of a distributor module (backplane bus) and a function module. Both modules are contacted via a 14-pole board-to-board plug. The bus signals on the distributor module are protected from interference by a shield support.
  • Page 41: Electronic Base Module Me02 / 2-Fold Bistable

    Type 8644 Structureandfunctionofthemodules 7.3.4. electronic base module me02 / 2-fold bistable Structure An electrical base module consists of a distributor module (backplane bus) and a function module. Both modules are contacted via a 14-pole board-to-board plug. The bus signals on the distributor module are protected from interference by a shield support.
  • Page 42: Electronic Base Module Me02 / 2-Fold 2 X Monostable

    Type 8644 Structureandfunctionofthemodules 7.3.5. electronic base module me02 / 2-fold 2 x monostable Structure An electrical base module consists of a distributor module (backplane bus) and a function module. Both modules are contacted via a 14-pole board-to-board plug. The bus signals on the distributor module are protected from interference by a shield support.
  • Page 43: Electronic Base Module Me03 / 2-Fold Monostable

    Type 8644 Structureandfunctionofthemodules 7.3.6. electronic base module me03 / 2-fold monostable Structure An electrical base module consists of a distributor module (backplane bus) and a function module. Both modules are contacted via a 14-pole board-to-board plug. The bus signals on the distributor module are protected from interference by a shield support.
  • Page 44: Electronic Base Module Me03 / 4-Fold Monostable

    Type 8644 Structureandfunctionofthemodules 7.3.7. electronic base module me03 / 4-fold monostable Structure An electrical base module consists of a distributor module (backplane bus) and a function module. Both modules are contacted via a 14-pole board-to-board plug. The bus signals on the distributor module are protected from interference by a shield support.
  • Page 45: Electronic Base Module Me03 / 3-Fold 10 Mm Monostable

    Type 8644 Structureandfunctionofthemodules 7.3.8. electronic base module me03 / 3-fold 10 mm monostable Structure An electrical base module consists of a distributor module (backplane bus) and a function module. Both modules are contacted via a 14-pole board-to-board plug. The bus signals on the distributor module are protected from interference by a shield support.
  • Page 46: Electronic Base Module Me03 / 2-Fold Bistable

    Type 8644 Structureandfunctionofthemodules 7.3.9. electronic base module me03 / 2-fold bistable Structure An electrical base module consists of a distributor module (backplane bus) and a function module. Both modules are contacted via a 14-pole board-to-board plug. The bus signals on the distributor module are protected from interference by a shield support.
  • Page 47: Pneumatic Base Module

    Type 8644 Structureandfunctionofthemodules 7.4. pneumatic base module 7.4.1. general description The pneumatic base module features the working connections for the following applications. Several modules can be placed in rows by connecting them. The seal on the outside is retained. The P-connection can be sealed by using a bulkhead.
  • Page 48: Pneumatic Base Module With Integrated P Shut-Off

    Type 8644 Structureandfunctionofthemodules non-return valve for the vent connections As certain applications require a functionality with non-return valves, there are also appropriate types for this purpose: • Without non-return valve, • Non-return valve in R, • Non-return valve in R+S, • An integrated P shut-off is also available for the modules MP11 (2-fold mono and 8-fold mono). mp11 mp12 G 1/8"...
  • Page 49 Type 8644 Structureandfunctionofthemodules procedure when replacing a valve CAuTIoN! • Only one valve may be removed at the same time. • During removal, observe that only the P channel is shut off! This means that a pressure on the working out- puts A or B is released when the valve is removed. This also means that a connected actuator is also depres- surized and a movement may be triggered as a result.
  • Page 50: Valves

    Type 8644 Structureandfunctionofthemodules 7.5. Valves 7.5.1. general description Automation systems are being used increasingly in all areas in which open and closed loop tasks are to be managed. The valves form the interface between electronics and pneumatics. The valves consist of a pilot control solenoid valve and a pneumatic valve. Pilot valve and valve housing are clamped or bolted to each other.
  • Page 51 Type 8644 Structureandfunctionofthemodules Valves Operating principle Operation Width type 3/2-way C (NC) Internal control air 6526 D (NO) C (NC) Control assist air (External) D (NO) C - vacuum (NC) 5/2-way Internal control air 6525 Control assist air (External) Internal control air 6527 Control assist air (External)
  • Page 52 Type 8644 Structureandfunctionofthemodules Valve switching time  Figure 27: Valve switching time If the valve is switched on for longer than 3 seconds, there are no restrictions for the duration until the valve is switched on again. For exact specification see data sheet of the particular valves. english...
  • Page 53: Installation

    Type 8644 Installation insTallaTiOn 8.1. safety instructions DANgEr! risk of injury from high pressure in the equipment! • Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines. risk of injury due to electrical shock! • Before reaching into the device or the equipment, switch off the power supply and secure to prevent reactivation! •...
  • Page 54: Removing The Valve Block From The Top-Hat Rail

    Type 8644 Installation 8.2. removing the valve block from the top-hat rail DANgEr! risk of electric shock! • Before reaching into the device or the equipment, switch off the power supply and secure to prevent reactivation! • Observe applicable accident prevention and safety regulations for electrical equipment! The valve block of the AirLINE system Type 8644 is combined with the decentralized peripheral system ET200S from Siemens.
  • Page 55 Type 8644 Installation → Detach the modules / terminals from the standard rail according to the manufacturer's description. NoTE! The interface of the left connection module contains elements which may break off if force is used. Ensure that the power module has been detached correctly and that there is adequate clearance in between. •...
  • Page 56: Installing The Airline System (E.g. In The Control Cabinet)

    Type 8644 Installation 8.3. installing the airline system (e.g. in the control cabinet) NoTE! • Before installation, check that the fastening rail is anchored firmly in the control cabinet or in the system. • Observe the specifications in the configuration file for the installation sequence. → Connect all electrical modules/terminals on the left of the valve block to the standard rail according to the manu- facturer's specifications.
  • Page 57: Fluid Installation

    Type 8644 Installation → Place new function module vertically on the distributor module (backplane bus) and press down until it clicks into position. → Connect valve, with the cleanly inserted flange seals / O-rings, to the valve slot and tighten the screws according to the following assembly diagram (see “Figure 30: Tightening the screws”).
  • Page 58: Pneumatic Connections - Feed

    Type 8644 Installation 8.5.1. pneumatic connections - feed (R/S) 3/5 Exhaust air X channel: Standard version: Deaeration of the control valves Control assist air version: P connection for control valves (P) 1 Pressure supply connection  Figure 31: Pneumatic connections Procedure → Depending on the version, insert (D10) or screw (G1/4, NPT 1/4) the connections to the corresponding working connections.
  • Page 59: Pneumatic Connections - Valve Discs

    Type 8644 Installation 8.5.3. pneumatic connections - valve discs NoTE! For 3/2-way valves the upper connections remain free! Inscription areas Working connections for 5/2-way valves Working connections for 3/2-way valves 4/2-fold valve discs  Figure 32: Pneumatic connections - valve discs Variants 5/2-way valves Variant 1 Variant 2 Variant 3...
  • Page 60: Electrical Installation

    Type 8644 Installation → Connection nipples can be used for threaded versions. Inscription of the connections: → Label the inscription areas with the data of the valve connections. 8.6. electrical installation DANgEr! risk of injury due to electrical shock! • Before reaching into the device or the equipment, switch off the power supply and secure to prevent reactivation! •...
  • Page 61: Maintenance, Troubleshooting

    Type 8644 Maintenance,Troubleshooting mainTenance, TrOuBleshOOTing 9.1. safety instructions DANgEr! risk of injury from high pressure in the equipment! • Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines. risk of injury due to electrical shock! • Before reaching into the device or the equipment, switch off the power supply and secure to prevent reactivation! •...
  • Page 62: Maintenance Of Components

    Type 8644 Maintenance,Troubleshooting malfunction possible cause remedial action Valves switch with Inadequate or no pressure supply Design the pressure supply with the largest a delay or blow off possible volume (even for upstream devices at the deaeration such as pressure controllers, maintenance units, connections shut-off valves, etc.) minimum operating pressure ≥ 2.5 bar...
  • Page 63: Start-Up

    Type 8644 Start-Up 10. sTarT-up 10.1. safety instructions WArNINg! risk of injury from improper operation! Improper operation may result in injuries as well as damage to the device and the area around it. • Before start-up, ensure that the operating personnel are familiar with and completely understand the contents of the operating instructions.
  • Page 64: 10.3.1. Selection Of The Modules In The Gsd File

    Type 8644 Start-Up 10.3.1. selection of the modules in the gsd file The module designations of the different electrical base modules in the GSD file can be found in the following table. add-on dimension module designation entry in gsd file ME02 / 2-fold monostable 2 Valves 3/2, 5/2 monostable 2DO 2 Valves 3/2, 5/2 monostable* 2DO ME02 / 2-fold 2 x monostable 2 Double Valves 3/2 monostable 4DO 11 mm...
  • Page 65: Packaging And Transport

    Type 8644 PackagingandTransport 11. pacKaging and TranspOrT NoTE! transport damages! Inadequately protected equipment may be damaged during transport. • During transportation protect the device against wet and dirt in shock-resistant packaging. • Avoid exceeding or dropping below the allowable storage temperature. english...
  • Page 66: Storage

    Type 8644 Storage 12. sTOrage NoTE! incorrect storage may damage the device. • Store the device in a dry and dust-free location! • Storage temperature: -20 ... +60°C 13. dispOsal → Dispose of the device and packaging in an environmentally friendly manner. NoTE! damage to the environment caused by device components contaminated with media. • Observe applicable disposal regulations and environmental regulations. Observe national waste disposal regulations.
  • Page 68 www.burkert.com...

Table of Contents