    ENGLISH INSTRUCTIONS FOR USE Slit lamp BM 900 ® 15. Edition / 2017 – 01 DOC. no. 1500 1500.1400209.04000 © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 1 21.02.2017 09:54:52...
  • Page 2 © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 2 21.02.2017 09:54:52...
  • Page 3: Table Of Contents

    Microscope and eyepiece ..................9 Decommissioning ..............9 Technical data ..............9 Slit illumination .......................9 Stereo microscope ....................9 Instrument base ....................10 Dimensions ......................10 © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 3 21.02.2017 09:54:52...
  • Page 4: Safety

    If this is the case, notify the transport company that has delivered the goods to you. Unpack the equipment together with a represen- © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 4...
  • Page 5: Light Toxicity

    • Haag-Streit expressly disclaims liability for incidental or consequential damage © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 resulting from the use of the product. •...
  • Page 6: Overview

    22. Stereo microscope with eyepieces 23. Eyepieces 24. Lens-changing lever 25. Mounting screw for the stereo mi- croscope 26. Centring screw © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 6 21.02.2017 09:54:55...
  • Page 7: Appliance Assembly / Installation

    (4) on the sides of the head rest. '10'. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 7 21.02.2017 09:54:56...
  • Page 8: Setting The Filters & Diaphragms

    40. Display of slit length in 1 to 8 mm flex-free examination with contact glasses (fundus and gonioscopy) and magni- (0 / -0.2), thickness 2.5mm 41. Blue filter fying glasses. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 8 21.02.2017 09:54:57...
  • Page 9: Fixation Star

    1x / 1.6x / 1x / 1.6x results in double pole disconnection from the mains. Eyepiece 10x / 10x / 25x / 25x © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 9 21.02.2017 09:54:58...
  • Page 10: Instrument Base

    An asterisk (*) shows that you should contact your HAAG-STREIT rep- be in the centre of the test rod. resentative for further information. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 10 21.02.2017 09:54:59...
  • Page 11: Legal Regulations

    © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 11...
  • Page 12: Concerning Electromagnetic Compatibility

    Emission of harmonics according to domestic purposes. EN 61000-3-2 Voltage fluctuations / flicker emissions Fulfilled according to EN 61000-3-3 © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 12 21.02.2017 09:55:00...
  • Page 13: Immunity (Standard Table 2)

    NOTE: U = the AC mains voltage prior to application of the test level. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 13 21.02.2017 09:55:00...
  • Page 14: Immunity For Non-Life Support Devices (Standard Table 4)

    fi eld strengths should be less than 10 V/m. Possible shorter distances outside the ISM bands do not contribute to improved application in this table. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 14...
  • Page 15: Safe Distances For Non-Life Support Devices (Standard Table 6)

    These guidelines may not apply in all situations. Electromagnetic wave propagation is influenced by absorption and reflection of buildings, objects and people. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 15...
  • Page 16 Gartenstadtstrasse 10 3098 Koeniz, Switzerland Phone +41 31 978 01 11 +41 31 978 02 82 eMail info@haag-streit.com Internet www.haag-streit.com © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04150 – 15. Edition / 2017 – 01 01_IFU_BM900-7200492-04150_eng.indd 16 21.02.2017 09:55:01...