13.3 Uninstall the external liquid supply

Disconnect the power to the appliance.
To deactivate the external liquid supply: The dip switches on the external liquid supply I/O board shall be set in OFF
position.

13.4 Pump signal schedule

Signal/Pump
1
2
3
4
ON
1
2
3
4
5
6
7
8
Chemical
Detergent
Bleach
Softener
Floor care
Used in
Program
Pre wash and main
wash
Main wash
Normal 60 and 95
Eco 60
Disinfection 60, 70
and 85
Last rinse
All programs except
Mop 60 and 85 and
Rinse
Last rinse
Mop 60 and 85
Rinse
Other info
Can be deselected by
the user with option
button