Alarm
Description
EH2
Supply voltage too high
EH3
Supply voltage too low
EH4
0Watt relay malfunction
Inconsistency between FCV relay (in
EHE
the main board) and safety
"sensing" circuit
Safety sensing circuit faulty (wrong
EHF
input voltage to microprocessor)
Possible fault
Problem with the power supply network (incorrect/disturbed); Main
PCB faulty.
Problem with the power supply network (incorrect/disturbed); Main
PCB faulty.
Main circuit board faulty.
Faulty cabling; Main circuit board faulty.
Main circuit board faulty.
55
Machine status/action
Wait for nominal
voltage conditions.
Wait for nominal
voltage conditions.
----------------
Safety drain cycle.
Cycle stops with door open.
Safety drain cycle.
Cycle stops with door open.
Reset
ON/OFF
ON/OFF
ON/OFF
RESET
RESET
RESET