Specifications - Toshiba UC1A1A020C6TB Operation Manuals

1400se series; 1400se plus series. single phase - 2.0/2.4 kva plus
Table of Contents

Advertisement

TOSHIBA
4.0

Specifications

4.1
Plus Series Specifications
Input
Battery
Battery backup time when fully charged
with 0.7 power factor at77° F (25° C)
Output
Output voltage regulation
Output voltage waveform
Rated load power factor
Voltage transient characteristic
Rated output current (rms)
Maximum output current (peak)
Inverter overload capacity
Environment
External dimensions (2 KVA 120V)
Switches
Interfaces
Fault detect and input power loss
Options
Software for unattended
(*) Output capacity reduced when input voltage is between -15% and -30% of nominal.
(**) Battery backup time may vary depending on the operating conditions and ambient temperature at the
installation site.
(***) An initial charge time of 24 hrs. is necessary to obtain proper battery performance level before unit is used
for battery backup.
(****) At 6000 ft (2000 m) above sea level, output capacity should be derated by 3%.
MODEL NUMBER
UC1A1A020C6TB
CAPACITY
2000 VA (1.4 kW)
Input voltage
Single phase, 120 Vac, +10% to -30% (*)
Input frequency
45 to 65 Hz
Input capacity
1920 VA
Input power factor
Approximate unity (0.98 to 1.0)
Battery rated voltage
96 Vdc
10 min. at full load (**)
30 min. at half load (**)
Recharge time
Maximum 24 hrs to 100% (90% recharge after 8 hrs) (***)
Type of batteries
Sealed lead-acid
Output voltage
Single-phase, 120 volts
Within +/- 3%, steady state
Output frequency
50/60 Hz +/- 0.5% in free-running mode (line sync range +/- 1Hz)
Computer-grade sine wave with less than 3.0% total harmonic
distortion with linear load
0.7 lagging (0.6 to 1.0)
+/- 5% under 100% load step change
16.7A
50.0A
150% for 60 seconds
Crest factor
3.0
Operating temperature
32 to 104° F (0 to 40° C), optimal at 77° F (25° C)
Storage temperature
-4 to 104° F (-20 to 40° C)
Operating humidity
30 to 90%, no condensation
Altitude(****)
Less than 3000 ft (1000 m) above sea level
10.00W x 25.50D x 22.50H (254W x 648D x 572Hmm)
Net weight
129 lb (58.6 kg)
Acoustical noise
45 dB at max. output, measured 3.3 ft (1 m) from front panel
Efficiency (ac-dc-ac)
85%
Bypass switch
Automatic bypass is provided when the run switch is in the off
position, if a fault occurs, or if an overload occurs (transfer time is
approximately 4 mS)
IBM (TM) AS/400
Pins 5 through 9
LAN Manager
Pins 2 and 3
Pins 1 and 4
RS232 ASCII
Pins 1 through 8
computer shutdown
Contact Toshiba for details on this option
External battery pack
Contact Toshiba for details on this option
DB9 male connector
DB9 female connector (Pin 9 not used)
4 - 1