4

TECHNICAL DATA

Supply voltage range (BMV600S / BMV-602S)
Supply voltage range (BMV-600HS)
Supply current (no alarm condition, backlight off)
BMV-600S/BMV602S
BMV-600HS
Input voltage range auxiliary battery (BMV-602S)
Input current range (with supplied shunt)
Operating temperature range
Readout resolution:
Voltage (0 ... 100 V)
Voltage (100 ... 385 V)
Current (0 ... 10 A)
Current (10 ... 500 A)
Current (500 ... 9999 A)
Amp hours (0 ... 200 Ah)
Amp hours (200 ... 9999 Ah)
State-of-charge (0 ... 100 %)
Time-to-go (0 ... 1 h)
Time-to-go (1 ... 240 h)
Voltage measurement accuracy
Current measurement accuracy
Potential free contact
Mode
Rating
Dimensions:
Front panel
Body diameter
Overall depth
Net weight:
BMV
Shunt
Material
Body
Sticker
18
@Vin = 24 VDC
@Vin = 12 VDC
@Vin = 144 VDC
@Vin = 288 VDC
9.5 ... 95 VDC
60 ... 385 VDC
3 mA
4 mA
3 mA
3 mA
9.5 ... 95 VDC
-500 ... +500 A
0 ... 50° C
±0.01 V
±0.1 V
±0.01 A
±0.1 A
±1 A
±0.1 Ah
±1 Ah
±0.1 %
±1 minute
±1 h
±0.3 %
±0.5 %
Normally open
60 V/1 A max.
69 x 69 mm
52 mm
31 mm
70 g
315 g
ABS
Polyester