11 TECHNICAL DATA

SmartShunt
Supply voltage range
Current draw
Input voltage range, auxiliary battery
Battery capacity (Ah)
Operating temperature range
Measures voltage of second battery,
temperature* or midpoint
Temperature measurement range*
VE.Direct communication port
RESOLUTION & ACCURACY
Current
Voltage
Amp hours
State of charge (0 – 100%)
Time-to-go
Temperature (0 - 50°C or 30 - 120°F)
Accuracy of current measurement
Offset
Accuracy of voltage measurement
INSTALLATION & DIMENSIONS
Dimensions (h x w x d)
Protection category
STANDARDS
Safety
Emission / Immunity
Automotive
Cables (included)
Temperature sensor
* Only when optional temperature sensor is connected, temperature sensor is not included
36
500A / 1000A / 2000A
6.5 - 70 VDC
< 1mA
6.5 - 70 VDC
1 - 9999 Ah
-40 +50°C (-40 - 120°F)
Yes
-20 +50°C
Yes
± 0.1A
± 0.01V
± 0.1 Ah
± 0.1%
± 1 min
± 1°C/°F
± 0.4%
Less than 10 / 20 / 40 mA
± 0.3%
500A: 46 x 120 x 54 mm
1000A: 68 x 120 x 54 mm
2000A: 68 x 120 x 76 mm
IP21
EN 60335-1
EN-IEC 61000-6-1
EN-IEC 61000-6-2
EN-IEC 61000-6-3
EN 50498
2 Cables with fuse for '+' and Aux connection
Optional (ASS000100000)