13.Remove the putty and unfasten the one nut at the top of
compressor holding the terminal cover.
Then remove the wiring connector of the compressor
cord.
14.Unscrew the five screws holding the connecting stay.
15.Unscrew the two screws holding the shroud cover.
16.Unscrew the six screws holding the condenser and
condenser shroud.
Two screws are on the back side.
Four screws are on the each side.
Unscrew the two screws holding the condenser cover .
17.Remove the condenser by liftting up about 1 inch and
pull it toward you and move to right.
18.Unfasten the one nut holding propeller fan by rotating it
clockwise. And remove the propeller fan.
19.Unscrew the three screws holding condenser shroud.
Note: Seal three female screws with siliconsealer
before re-installing.
20.Unscrew the four screws holding the evaporator.
Two are on left side.
Two are on right side.
21.Remove the evaporator.