Operation And Maintenance - Bosch 8981 021 140 Assembly Manual

Adjustable height workstation
Table of Contents

Advertisement

Operation and Maintenance

Initializing the Telescoping actuators
Before putting the Adjustable Height Workstation into
operation, connect the unit to a properly grounded 110
VAC receptacle and perform the following initialization
test.
1. Press the "Down" arrow on the Switch Panel. Hold
the button down, the desk will stop moving.
2. Continue holding the "DOWN" arrow. After about 5
seconds the desk will begin to slowly move again. It
will continue moving down until it reaches the absolute
end of the travel position and then stop.
3. Release the "DOWN" arrow and disconnect the
electrical cord. The desk is now ready to be put into
operation.
Operation
Before using the Adjustable Height Table for the first
time, use a square to re-check all profiles for
perpendicularity, and double check all mounting hardware
for tightness.
Locate the wokstation in the work cell. Be sure there is
a convienient power outlet within reach of the plug on the
workstation. Use a level and adjust the leveling feet until
the workstation is level from side to side and front to
back. For maximum stability, Bosch Rexroth recommends
anchoring the workstation to the floor. A number of
anchoring options can be found in the Bosch aluminum
structural framing catalog available through your local
distributor.
Plug the workstation into a properly grounded 110 VAC
receptacle. Press the "UP" arrow on the switch assembly.
Observe the workstation as it moves. Make sure that no
excessive strain is placed on any of the electrical wires
as the workstation is raised to its fully extended position.
Press the "DOWN" arrow on the switch assembly.
Again, observe the electrical wires to verify that none of
them will be pinched or severed as the workstation
moves to its fully lowered position.
When using the Adjustable Height Workstation, be sure
the weight on the worksurface is centered and evenly
distrubuted. Maximum load is 400 lb (181.5 kg).
• DO NOT place entire load on one edge of the
worktable surface.
• DO NOT lean on the table top.
• DO NOT sit or stand on the table top.
• DO NOT exceed the maximum moment of 500 Nm
or tipover may occur (see the Caution on page 4).
• DO NOT use table tops wider than 1400 mm.
• DO NOT exceed the maximum payload of 400 lb
(181.5 kg).
Maintenance
CAUTION: Disconnect power before
beginning maintenance work of any type.
The telescoping acturators used in the Adjustable Height
Table Frame Kit are maintenance-free. The following
cleaning and adjustment procedures, however, will help
keep your work table in almost new condition if performed
on a regular basis.
1. Remove all dirt and grease. Wipe the table clean of
any excess grease, dirt or any foreign substances
every month.
2. Re-tighten all fasteners. Check all fastening elements
for tightness, and re-tighten to 25 Nm (18 lb-ft) if
necessary.
3. Check the power cord for cracks and fraying.
4. If at some point the telescoping actuators become
uneven or out of syncronization, perform the initializing
procedure at the top of this page.
23

Advertisement