Final Assembly

Mount the switch assembly with slider plate to the
table top using the pilot holes drilled previously. Use
the 3 screws that came with the switch. See inset
drawing #1 on Figure 17.
CAUTION: The plugs on the switch cable and
telescoping actuator cables are polarized and
will fit only one way in the control box and
telescoping actuator connector sockets. Use
care not to bend the pins when making these
connections.
Plug the free end of the cable on the switch into the
connector socket HS on the control box.
Plug one end of a telescoping actuator cable into the
connector on one of the telescoping actuators. Plug
the other end of the cable into MOT 1 on the control
box.
Control
Box
Cross Brace
Figure 17
Cable Carrier
and Tie
Profile
Plug one end of a telescoping actuator cable into the
connector on the other telescoping actuator. Plug the
other end of the cable into MOT 2 on the control box.
Insert a cable carrier into the side slot on the table top
cross brace and twist 90° to lock it in place. See Inset
#2. Then insert a cable tie through the slot on the
cable carrier and around the cables.
In the same manner, install cable carriers and cable
ties at the other 3 locations on the table top cross
braces.
This completes the assembly of the Adjustable Height
Workstation. With the help of an assistant, position
the workstation upright and proceed to Operation
and Maintenance on the next page.
Cable
Carrier
3.5x22
Cable Carrier
Pan Head
and Tie
Screw
Cable
Tie
INSET #2
INSET #1
Switch
Slider
Plate
Pilot
Holes