Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Overview of the iSwitch 7xx series iSwitch 74x (740, 741, 742)* 7-port switch with 1 (741) or 2 fiber-optic ports (742) 3x24VDC (S1, S2,*) supply voltage 1x48VDC (S4) supply voltage (PoE) 1x48VDC (S5) – PoE supply via TP port 1 according to IEEE802.3af (Class 2(0))
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Contents Overview of the iSwitch 7xx series....2 Signalling contacts, alarms ......16 Contents ..............2 Summary of options ........17 Standard version..........17 Contents ..............3 24VDC version ..........17 48VDC version ..........17 Features...............4...
Up to 8 different categorisable trap and/or syslog LAN interface receivers iSwitch 740 – 7 x Twisted Pair (TP) ports V24 (RS232) setup and configuration interface iSwitch 741 – 6 x TP + 1 x fiber-optic (FO) ports Memory card (MMC) for storing configuration iSwitch 742 –...
Page 5
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Optical interfaces according to IEEE802.3u PoE PSE Power Source Equipment (S4) 100BASE-FX / 100BASE-SX External powering of attached devices via the TP TX and RX wavelengths 1300nm/850nm (SX) or data line (endpoint insertion mode B – unused 1550nm/1300nm for SF5 or 1300nm/1550nm for pairs 4-5, 7-8) on TP ports 2…5...
74x Function and application The Nexans iSwitch 7xx series makes switching technology possible in the local loop. This series emphasizes cost- effectiveness and flexibility by making up to sixfold use of a central LAN connection – the so-called Uplink.
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Functionality The self-learning switch works according to the store-and-forward principle. In full-duplex mode it supports flow control according to IEEE802.3x and in half-duplex mode it supports the backpressure feature. The system has been designed for Power over Ethernet (PoE) features. A maximum of 4 users can be supplied with power (PoE PSE).
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Overview (iSwitch 74x) (Example: iSwitch 742 SFP) Power supply status Function and status indicators (switch) S1, 2 = 24VDC version S4, (5) = 48VDC version or PoE Uplink: 1x RJ45 TP socket user port (10/100Mbps) Power over Ethernet (PD) –...
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Safety instructions When this unit left the factory it was in perfect working order. To operate it without risk, and to ensure it remains in good working condition, the following safety instructions must be observed.
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Instructions on repair and maintenance Any repairs must be executed workmanlike. The design features of the unit must not be altered in a way that impairs the safety of the unit. This in particular applies to leakage paths and clearances.
External power supply (S5) – PoE (PD) By default (exception: 24V version) the Nexans i-series has been designed in such a way that the i-systems can be powered as a standard-compliant powered device (PD) via the appropriate Twisted Pair port 1. IEEE802.3af – PD modes A and B are supported.
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Dismounting (standard version) The system is dismounted in reverse order compared with the mounting procedure. Metal mounting rail: To the release racketeers contrary to the feather-strength downward pulls / levers. Lift the system-front.
DIP 2 = ON -> unit in Standby mode, internal operating voltage disabled (jumper across Disable contacts) Designation Colour Description Switch status: iSwitch 740, 741, 742 Lights up, if internal operating voltage is present. green State Port configuration monitoring OK green –...
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Designation Colour Description Port status: 1..5, 6, 7 a) Lights up permanently when the link signal is received at the Link green TP interface b) Flashes periodically when data packets are received or sent...
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x DIP configuration switch (rear panel) (Only for systems without Management option.) Signalling/alarm: Designation Description DIP 1 M1 is enabled: S4 (48V) failure or not used. M2 is enabled: DIP 2 Unit in Standby mode, internal operating voltage...
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Signalling contacts, alarms Signalling/alarm M1 LED DIP switch Description Overall power failure S4 (48V) failure or not used. DIP 1 = ON Link loss on TP port 1 DIP 10 = ON...
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Summary of options Standard version 1. 24VDC power supply, redundant S1, S2 2. 48VDC power supply, S4 3. PoE (PD) power supply via TP port 1 (S5) Universal flexible systems for use in industrial environments with multiply redundant power supplies including external power supply via PoE.
Ethernet cable. The Nexans i-Series for industrial applications uses the so-called PoE (Power over Ethernet) feature. Thus no hybrid cables, where power is supplied vie separate lines, are used.
Manual - Nexans Local Configurator V3 (NexConV3) – describes an easy-to-use Windows application which facilitates the local configuration of the IP parameters and switch names. Manual - Nexans Switch Manager V3 (NexManV3) – describes an easy-to-use Windows application which facilitates the local configuration of the IP parameters and switches.
Page 20
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x • A hardware reset is equivalent to a short interruption of power supply. - 20 -...
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x SET configuration pushbutton (front panel) - Mgmt (Only for systems with integrated Management option.) The Set configuration pushbutton of the iSwitch 7xx series is installed on the front panel (down on the right). It can be accessed above the Set indicator via a whole in the front panel.
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x DIP configuration switch (rear panel) - Mgmt (Only for systems with integrated Management option.) Signalling/alarm: Designation Description DIP 1 M1 is enabled: S4 (48V) failure or not used. M2 is enabled: DIP 2...
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Option: MMC memory card for i-system (Only for systems with integrated Management option.) The iSwitch 74x system family allows you to use a memory card for service, backup or configuration purposes. The memory card is used in connection with the Management option: The card is intended for storing configuration data and offers the user additional flexibility.
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x General configuration notes and recommendations Setting the transmission parameters Frequently many problems occurring in data networks can be avoided. Based on our long years of practical experience we can recommend the following settings for the iSwitch 74x series:...
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x MDI/MDI-X Auto-Crossover MDI/MDI-X Auto-Crossover is an optional function of the IEEE802.3 standard which is specified in its Chapter 40.4.4. The aim of this standard is to eliminate the need for crossed connecting cables between Ethernet devices.
Page 26
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Note: Over the past years quite a number of manufacturers such as CISCO, Alcatel etc. have introduced proprietary PoE solutions into the market which differ from the standard. In this case caution is required. However, within the framework of our flexible options some of those adaptations are possible (see Options).
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Technical Data General and mechanical specifications Unit Parameter Model Enclosure for rail mounting 35 mm DIN in accordance EN 60715 (EN 50022) Desktop enclosure Option: wall-mounting, edge protection Use area Industry, stationary usage...
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Power supply (S1,S2) Parameter Unit min. typical max. Input voltage VDC 18 Current input 0.25 Power consumption Interface connector 24V power supply S1, S2 4-pin terminal block, screw-on type (front panel) PoE (PSE) power supply (S4) Input voltage Input current, S1..2 used,...
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x Switch – functional parameters Parameter Unit min. typical max. Switching method Store and forward, self-learning Data throughput per port 148800 Packets/sec. Packet buffer kbyte MAC address table, entries 8192 Number Aging timer...
Page 30
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x General features Parameter Unit DIP:iSwitch 740 Configuration switch, 10-pin, M1 -> S4 (48V) Fail only without Management option M2 -> Disable active (rear panel) Port1 -> 100 FDX Port 1 -> AN / 10/100 HDX* Port2 ->...
Port 6 10/100 (FO=100) Mbps Port 7 Electrical interfaces (TP) for connecting users on port 1..7, 6, 5 depending on iSwitch 740, 741,742 type Input/output signals Standard In accordance with IEEE802.3 10BASE-T, full-, half- duplex and/or IEEE802.3u 100BASE-TX, full-, half- duplex Interface connector port 1...5, 6.
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x LAN interfaces Parameter Unit min. typical max. (only iSwitch 742 SFP) SFP interfaces Input/output signals (100 Mbps) Port 6, 7 according to IEEE802.3u 100BASE-X (SERDES) Standard as a function of the optional SFP module...
Page 34
Nexans Active Networking Systems Industrial Ethernet iSwitch 74x - 34 -...
Page 35
Industrial Ethernet iSwitch 74x Nexans network solutions are used throughout the world and have proved their reliability in many different ways. Our references include leading companies in the world, universities, industrial properties, hospitals, authorities and banks. A LAN System which can grow with the needs of its users has to be designed right from the very start with such a level of flexibility to ensure that support is provided in particularly with frequent moves, adds and changes.