Disassembly and Reassembly
5.15 Connection PCB
1. Before you remove the Connection PCB, you should
remove:
- Side Cover Right (Refer to 5.7.3)
2. Unplug the all connectors.
Connection
PCB
3. Remove the two screws securing the Connection
PCB and remove it.
Service Manual
5-24
4. The connectors are located, as shown below.
Duplex Motor
Connection
PCB
Fuser Exit Motor, Duplex Fan
FAN MAIN
HVPS